Panasonic A4P Series Benutzerhandbuch

Seite von 232
215
[Supplement]



Supplement
* These are subject to change. Contact us when you use these values for your machine design.
• MDMA302 * 1 *
   Input voltage to driver: AC200V
   (Dotted line represents torque at 10% less voltage.) 
• MDMA402 * 1 *
   Input voltage to driver: AC200V
   (Dotted line represents torque at 10% less voltage.) 
• MDMA502 * 1 *
   Input voltage to driver: AC200V
   (Dotted line represents torque at 10% less voltage.) 
• MFMA042 * 1 *
   Input voltage to driver: AC200V
   (Dotted line represents torque at 10% less voltage.) 
MDMA series 
(3.0kW to 5.0kW)
With oil seal
MFMA series 
(400W to 4.5kW)
With oil seal
• MFMA152 * 1 *
   Input voltage to driver: AC200V
   (Dotted line represents torque at 10% less voltage.) 
• MFMA252 * 1 *
   Input voltage to driver: AC200V
   (Dotted line represents torque at 10% less voltage.) 
• MFMA452 * 1 *
   Input voltage to driver: AC200V
   (Dotted line represents torque at 10% less voltage.) 
torque
[N
m]
* Continuous torque vs.
  ambient temp.
* Continuous torque vs.
  ambient temp.
torque
[N
m]
torque
[N
m]
* Continuous torque vs.
  ambient temp.
torque
[N
m]
* Continuous torque vs.
  ambient temp.
* Continuous torque vs.
  ambient temp.
torque
[N
m]
torque
[N
m]
* Continuous torque vs.
  ambient temp.
torque
[N
m]
* Continuous torque vs.
  ambient temp.
25
0
50
speed [r/min]
1000
2000
3000
Peak running range
Continuous running range
50
0
10
20
30
40
100
ambient temp. [˚C]
ratio vs. rated torque [%]
(42.9)
(14.3)
0
10
20
30
40
100
85
70
50
ambient temp. [˚C]
25
0
50
speed [r/min]
1000
2000
3000
without
brake
with
brake
Peak running range
Continuous running range
ratio vs. rated torque [%]
35
0
70
speed [r/min]
1000
2000
3000
0
10
20
30
40
100
90
85
50
ambient temp. [˚C]
Peak running range
Continuous running range
ratio vs. rated torque [%]
(18.8)
(56.4)
(71.4)
(23.8)
2.5
0
5
speed [r/min]
1000
2000
3000
Peak running range
Continuous running range
50
0
10
20
30
40
100
ambient temp. [˚C]
ratio vs. rated torque [%]
50
0
10
20
30
40
100
ambient temp. [˚C]
ratio vs. rated torque [%]
10
0
20
speed [r/min]
1000
2000
3000
Peak running range
Continuous running range
(5.3)
(21.5)
(7.15)
(1.9)
15
0
30
speed [r/min]
1000
2000
3000
Peak running range
Continuous running range
50
0
10
20
30
40
100
ambient temp. [˚C]
ratio vs. rated torque [%]
25
0
50
speed [r/min]
1000
2000
3000
Peak running range
Continuous running range
50
0
10
20
30
40
100
ambient temp. [˚C]
ratio vs. rated torque [%]
(30.4)
(11.8)
(54.9)
(21.5)
• When you lower the torque limit setup (Pr5E and 5F), 
  running range at high speed might be lowered as well.
torque 
speed
Continuous running range
Running range (Torque limit setup : 300%)
Running range (Torque limit setup : 200%)
Running range (Torque limit setup : 100%)
without
brake
with
brake