MGE UPS Systems 100 Benutzerhandbuch

Seite von 30
Page 12 - 
34003602EN/AB
1. Presentation
1.4 Technical data sheet
Functions
RS232 Port
RS485 Port
Modem
Contact inputs
Power supply
(external version)
Characteristics/Default values
 9600
 8
 1
 None
 1200, 8, 1
 None
 2 wires
 Master
 With
 Without
 0.08 - 0.6 mm
2
 (28/20 AWG)
 V.34/33.6 kbps
 Error correction: V.42 LAPM and MNP 2-4
 Data compression: V.42b and MNP5
 Works with 39 country profiles
 European  CTR21 compatibility
 Line protection included
 Normally open (NO)
0.08 - 0.6 mm
2
 (28/20 AWG)
 2 (card version)
 2+4 (external version) 0.08 - 0.5 mm
2
 (28/20
 
AWG)
 10m maximum
 5V DC
 1A
Parameters
 Rate
 Data bits
 Stop bits
 Parity
 Rate, bits, stop
 Parity
 Mode
 Master / slave
 Bias
 Impedance matching
 Cable cross-section
 Analogue
 Country
 Protection
 Dry contacts
 Number
 Distance
 Voltage
 Current
Possible values
 9600
 8
 1
 Even, odd
 See technical support
documentation
 2 wires / 4 wires
 Master
 With / without
 With / without
 NO / NC
 0 to 2
 0 to 6
Comment: only MGE UPS SYSTEMS can be connected to the RS485 link.