Adding or Removing Cabinet Hardware 
6-104
Add a Switch Node Carrier (Standard Reliability) 
6
Install Circuit Packs
1. Install the new circuit packs into carrier “D.” Use the decal and the 
upgrade configuration document (provided with the equipment) as a 
guide.
2. Install circuit pack blanks in slots not equipped with circuit packs.
Interconnect Port Networks
1. Behind the cabinet containing the switch node carrier (See 
):
a. Connect the metallic intracarrier cable (H600-278) to slots 1D01 
and 1D02.
2. Behind switch node carrier D of PPN cabinet 1 (See 
):
a. For each EPN, install 1 lightwave transceiver on a cable connector 
with the following order of slots: 1D20, 1D03, 1D19, 1D04, 1D18, 
1D05, and so forth.
b. Connect 1 end of a fiber optic cable to each lightwave transceiver, 
just installed.
c. Carefully attach the fiber optic cables (with cable ties) to the wall of 
the cable tray at the built-in cable-tie positions.
3. Behind processor carrier A of each EPN cabinet:
a. Install a lightwave transceiver on cable connector at slot 1A01.
b. Connect the other end of the fiber optic cable to the lightwave 
transceiver, just installed, at slot A01.
c. Carefully attach the fiber optic cable (with cable ties) to the wall of 
the cable tray at the built-in cable-tie positions.
d. Coil up the surplus length of fiber optic cable, and carefully attach 
the coil to the wall of the cable tray.
Table 6-9.
TDM/LAN Connections
“J” Number
Carrier Type
LHS Slot
RHS Slot
J58890BB L1
Port
21
02
J58890BB L2
Port
21
01
J58890BB L3
Port
21
01
J58890AP
Control
21
02