Mitsubishi Electronics 882.00273.00 Benutzerhandbuch

Seite von 101
•  Three (3) types of recipe entry procedures available: 
o
  Quickset mode (up to 6-component) recipe entry.  Color and additives are 
metered as a percentage of the virgin material. 
o
  Percentage mode recipe entry. Ingredients are metered as a percentage of 
the overall batch. 
o
  Parts mode recipe entry (i.e. 500:1)  Ingredients are metered as a ratio to 
each other within the batch 
•  Full control diagnostics  
•  Serial printer and RS-485 communications ports 
System Component Description 
This section describes the various components of the blending system. 
Supply Hoppers 
The material supply hoppers are located on top of the blender frame. These hoppers store a 
supply of material for the individual metering devices. They are sized based on the total 
throughput of the blender. 
The blending system does not include any level indication devices on the unit. Optional low-
level sensors are available.  The blender controller will alarm if it runs out of material while 
trying to make a batch, but low-level sensors will alert floor personnel to the problem sooner. 
Each hopper is equipped with a sight glass and/or access door.  
Figure 5:  Typical Hopper Assembly 
 
 
BF1-615.3 
Chapter 2: 1BFunctional Description 
16 of 101