Samsung SPD-3750 Benutzerhandbuch

Seite von 41
SPEED DOME CAMERA
User’s Manual
72
SPEED DOME CAMERA
User’s Manual
73
Alarm Output
 
Setting1 
MD 
TRK
 
Setting2 
MD 
TRK
 
Timer 
1 OFF 
 
Timer 
1 OFF
  Alarm Setting
 
Alarm Enable 
OFF
 
Alarm Input 
 
 
Alarm Output 
 
Aux Output
  Main Menu
 
Camera Setting
 
Sequence Setting
 
P/T Setting
 
OSD Setting
 
Alarm Setting
 
Initialize
 
Status
25.2. Alarm Output
Main Menu/Alarm Setting/Alarm Output
  Setting 1,2 : 
  Enables selecting an Alarm Output method.
  -  1, 2, 3, 4, and MD on the menu selection indicate the 
alarm input port and motion detection input. Up to 4 
alarm inputs can be set for each MD (Motion Detection) 
and TRK (Auto Track). 1 alarm output port can be used for 
more than 2 alarm inputs along with ones for MD and 
TRK.
  Timer : 
  Enables selecting an Alarm Output method.
  - On :  Retains an alarm output for a set duration from a 
minimum of 1 second to a maximum of 60 hours 
upon the alarm occurrence.
  - Momentary :  Retains an alarm output only until the alarm 
is canceled.
  The TRK function becomes activated only if the Zone mode 
under Zone Settings under Auto Track 2 is set to Alarm.
  The Alarm Output is equipped with a relay circuit. The 
operation of the alarm output port is as shown in the 
diagram below. 
•ConnectingthepowerconnectorandGNDincorrectlytotheNC/NOandCOMportsmay
cause a short circuit and fire, damaging the camera.
•Themaximumpowercapacityofthebuilt-inrelayis30VDC/2A,125VAC/0.5A,and
250VAC/0.25A. Operating the camera beyond the capacity may decrease the camera’s 
lifespan and damage it.
Notes
NO
NO
NC
NC
COM
COM
Alarm Out OFF
Alarm Out ON
  Alarm Setting
 
Alarm Enable 
OFF
 
Alarm Input 
 
 
Alarm Output 
 
Aux Output
  AUX Output
 
On/Off 
OFF
 
Time 
00 SEC
  Main Menu
 
Camera Setting
 
Sequence Setting
 
P/T Setting
 
OSD Setting
 
Alarm Setting
 
Initialize
 
Status
25.3. Aux Output
Main Menu/Alarm Setting/Aux Output
•ConnectingthepowerconnectorandGNDincorrectlytotheAuxterminal’sNOandCOM
ports may cause a short circuit and fire, damaging the camera.
•Themaximumpowercapacityofthebuilt-inrelayis30VDC/2A,125VAC/0.5A,and
250VAC/0.25A. Operating the camera beyond the capacity may decrease the camera’s 
lifespan and damage it.
Notes
AUX Output menu is to operate the camera’s peripheral 
devices such as lamps and sirens through the controller and 
switches as well as through network communications. 
  On/Off : 
  -  Cancels or activates the Aux function.
  Time : 
   Enables setting up a duration for the Aux output when the 
Aux command is transmitted from the controller. A 
duration can be selected from a minimum of 1 second to a 
maximum of 60 minutes.
NO
COM
AUX Off
NO
COM
AUX On
Functional Description
Functional Description