Cornelius 3 Benutzerhandbuch

Seite von 74
Viper Service Manual                                   
Publication Number: 621360041TBSER
- 44 -
© 2010, IMI Cornelius Inc.
S
EMI
-A
NNUAL
 M
AINTENANCE
There are several procedures that should be completed on a semi-annual basis. 
There procedures help to insure proper operation of the system on a long term 
basis. Refer to Table 33 for a listing of the semi-annual maintenance items.
Inspecting and Replacing Scraper Blades
Scraper blades should be inspected for wear during the semi-annual mainte-
nance check. To inspect the blades, perform the procedure in Table 35
Cleaning the Syrup Connections
Syrup connections should be cleaned at least every six months, or when syrup 
types are changed. Perform the procedure in Table 36 to clean the BIB connec-
tors.
Table 35
Step
Action
1. 
2. 
When purging is complete, remove power from the unit.
3. 
Remove the four (4) 3/4 in. nuts from the faceplate and slowly remove the 
faceplate from the unit.
4. 
Slowly pull the blade assembly out of the barrel.
5. 
Rinse and inspect the blade assembly for signs of wear.
6. 
If there is significant wear on the blades, Reverse or replace them, depending 
on the wear pattern.
7. 
Replace the blade assembly and bushings (PN 2392) onto the motor shaft in 
the barrel.
8. 
Re-install the faceplate and replace the four (4) mounting nuts. Hand tighten 
the nuts untill the faceplate makes contact with the gasket, then use a wrech 
to tighten the nuts an additional 1/4 turn. Be careful not to over tighten the nuts 
or cracking of the faceplate may result.
9. 
Refill the barrel with product. See “Filling a Barrel” on page 29.
10. 
When barrel fill is complete, perform a motor calibration. See “Calibrating a 
Table 36
Step
Action
1. 
Open the merchandiser and select OFF for the barrel to be cleaned.
2. 
Remove the quick disconnect from the BIB container.
3. 
Fill a suitable pail or bucket with soap solution.