Smeg C6GVXI Benutzerhandbuch

Seite von 23
Instructions for the installer
81
4.2 Burner and nozzle characteristics table (60 cm model);
Burner
Rated heating 
capacity (kW)
LIQUID GAS – G30/G31 28/37 mbar
Nozzle 
diameter 1/
100 mm
By-pass
1/100
mm
Reduced 
capacity
(W)
Capacity
g/h G30
Capacity
g/h G31
Auxiliary
1.0
50
30
400
73
71
Semi rapid
1.8
65
33
500
127
125
Ultra-rapid
4.0
100
65
1600
290
286
Oven
3.2
87
50
900
233
229
Burner
Rated heating 
capacity (kW)
LIQUID GAS – G30/G31 28/37 mbar
Burner
Rated heating 
capacity
(kW)
TOWN GAS – G110 8 mbar
Nozzle
diameter
1/100 mm
Reduced
capacity
(W)
Auxiliary
1.0
145 (/8)
400
Semi rapid
1.8
185 (/2)
500
Triple crown
4.0
350 (/13)
1200
Oven
3.2
270
900
The nozzles and data concerning TOWN GAS are available at the Authorised Service Centres.
Burner
Rated heating 
capacity
(kW)
NATURAL GAS – G20/G25 20/25 mbar
Nozzle
diameter
1/100 mm
Reduced
capacity
(W)
Auxiliary
1.0
72 (X)
400
Semi rapid
1.8
97 (Z)
500
Ultra-rapid
4.0
135 (K)
1600
Oven
3.2
130
900