REQUIRED REGULAR MAINTENANCE:
Semi Annual:
 
Bunn Kit #34245.0001 is required for ULTRA-1 and 
#34245.0000 is required for ULTRA-2, to perform the 
semi annual Preventive maintenance:
Note: Service caused by failure to perform required 
maintenance is not covered by warranty.
 
The following instructions apply to one hopper only; 
repeat each step for all hoppers.
Kit Contents 
Inventory the kit for completeness before proceeding.
 
34245.0000  PM Kit, ULTRA-2
 
** 
34245.0001  PM Kit, ULTRA-1
Part Number  Qty. 
Description
 
*  **
27446.0000 
2  1 
Lamps, T-5 Wedgebase Min.
26781.0000 
2  1 
Auger Shaft Bushing (Blue)
26782.0001 
2  1 
Cooling Drum Seal
32079.0000 
2  1 
Hopper/Drum Seal
32268.0000 
2  1 
Seal, Faucet (Clear)
29563.0000 
-  - 
Lubricant (“Krytox”)
28395.0000 
1  1 
Seal Insertion Tool
FIG 1
Auger Motor Cover
Auger Motor Assy
Auger Shaft Assy
Cooling Drum
Hopper/Drum Seal
Auger Shaft Bushing
Cooling Drum Seal
P2528
Run Capacitor
INSTRUCTIONS
WARNING - Disconnect the dispenser from the power source before the removal of any panel or the replacement 
of any component.
1.  Drain, remove and clean hopper; refer to the Operating and Service Manual for proper cleaning procedures. 
Discard the hopper/drum seal and faucet seal. 
2.  Remove the #8 locking screws securing auger motor cover to the cooling drum mount assembly; remove 
cover and set aside for reassembly.
3.  Remove the #8 locking screw on the lower right side (viewed from front) of the auger motor mounting bracket 
securing the auger motor run capacitor. Set capacitor aside with wires attached.
4.  Disconnect the auger motor terminal from the terminal on the main wiring harness.
5.  Remove the remaining #8 locking screws securing the cooling drum mounting bracket. Remove motor with 
mounting bracket.
NOTE:  When removing or installing motor and shaft assembies, be sure the motor and shaft pins are turned to 
a position that will clear the torque sensor circuit board.