Vulcan g260l Техническое Руководство

Seite von 2
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791
QUOTE & ORDER FAX: 1-800-444-0602
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and
specifications without notice.
6.00
24.50
(622)
8.00
(152)
13.25
(337)
(864)
34.00
(203)
(616)
24.25
(914)
36.00
30.00
(762)
(660)
26.00
CONVECTION OVEN CAVITY DIMENSIONS
26.00 (660) WIDE
27.25 (692) DEEP
11.50 (292) HIGH
OVEN
MOTOR "C" UNITTS ONLY
2.00
(25)
(51)
1.00
23.25
(591)
12.00
(305)
(13)
.50
1" NPT GAS CONNECTION
(152)
12.00
TYP
(305)
(305)
12.00
60.00
(1524)
24.00
(610)
6.00
(152)
(305)
12.00
6.00
(864)
34.00
ELEC. CONN. "C"
UNITS ONLY
115V., 60C. ELEC
SUPPLY CORD 7' LONG
(2134 mm)
OVEN
2 PLACES
(762)
30.00
(1448)
57.00
6.00 MIN (152)
8.00 MAX (203)
(111)
4.375
F-36856 (3-06)
G260L SERIES
GAS RESTAURANT RANGE
IMPORTANT
1. A pressure regulator sized for this unit is included. Natural
gas 4.0" W.C., propane gas 10" W.C. manifold pressure.
2. This range is supplied with a 1" rear gas connection. For
maximum performance or where supply pipe lengths are
greater than 2 ft. long, we recommend a 1" supply line. If a
flexible connection is used, the connection must be rated
for the total gas input requirements of the range.
3. An adequate ventilation system is required for commercial
cooking equipment. Information may be obtained by writing
to the National Fire Protection Association, Batterymarch
Park, Quincy, MA 02289. When writing, refer to NFPA
No. 96.
4. Entry clearance for the G260L is 43" crated and 34"
uncrated. If necessary, the front ledge and oven door
handle may be removed by unscrewing 7 screws for a 30"
clearance.
5. Clearance:
Combustible
Non-Combustible
Rear
6"
0"
Left Side
10"
0"
Right Side
10"
0"
6. This appliance is manufactured for commercial installation
only and is not intended for home use.