Aten kh-0116 Benutzerhandbuch
Appendix
51
Administrator Login Failure
If you are unable to perform an Administrator login (because the Username and
Password information has become corrupted or you have forgotten it, for
example) you can clear the login information with the following procedure:
Password information has become corrupted or you have forgotten it, for
example) you can clear the login information with the following procedure:
1. Power off the KH0116 and remove its housing.
2. Short the jumper labeled J12.
3. Power on the switch.
The on screen display will show a message informing you that the
password information has been cleared.
password information has been cleared.
4. Power off the switch.
5. Remove the jumper cap from J12.
6. Close the housing and start the KH0116 back up.
After you start back up, you can use the default Username and Password (see
OSD Overview, p. 33) to log in.
OSD Overview, p. 33) to log in.
HD15-F
HD15-F
HD15-F
HD15-F
HD15-F
HD15-F
HD15-F
HD15-F
PC1
PC2
PC3
PC4
PC5
PC6
PC7
PC8
CHAIN IN
CHAIN OUT
CMS
CKB
CVGA
1
1
1
1
1
1
LEA-A
FWDL-B
7SEG-A
PW-JACK
250-B1
250-B2
1
J12
Restore
Default
Password
Default