Bunn VP17 Betriebsanweisung

Seite von 19
Page 12
If voltage is not present as described, refer to the Wiring 
Diagrams and check the brewer wiring harness.
5.  With the black wire removed, remove the wire from 
the lower terminal. 
6.  Check for continuity across the center and lower 
terminal with the switch in the "ON" (upper) posi-
tion.  Continuity  must  not  be  present  when  the 
switch is in the "OFF" (lower) position.
If continuity is present as described, reconnect the 
black wire to the center terminal and the remaining 
wire to the lower terminal.
If continuity is not present as described, replace the 
switch.
Removal and Replacement:
1.  Remove the wires from the switch terminals.
2.  Remove front end cap.
3.  Compress  the  clips  inside  the  hood  and  gently 
push the switch through the opening.
4.  Push the new switch into the opening and spread 
the clips to hold switch in the hood.
5.  Reinstall front end cap.
6.  Refer to Fig. 7  when reconnecting the wires.
P1918
SERVICE (cont.)
ON/OFF WARMER SWITCH 
Location:
 
The ON/OFF warmer switch(es) are located on the  
front of the hood.
Test Procedure:
1.  Disconnect the brewer from the power source.
2.  Viewing  the  switch  from  the  back,  remove  the 
white wire from the upper terminal and the black 
wire from the center terminal.
3.  With  a  voltmeter,  check  the  voltage  across  the 
white wire and the black wire. Connect the brewer 
to the power source. The indication must be:
 
a) 100 volts ac for two wire 100 volt models.
 
b) 120 volts ac for two wire 120 volt models.
4.  Disconnect the brewer from the power source.
If voltage is present as described, reconnect the white  
wire and proceed to #5.
P1166.40
FIG. 6 ON/OFF WARMER  SWITCHES
FIG. 7 ON/OFF SWITCH TERMINALS
10860  061501
ONE LOWER WARMER
TWO WARMERS
THREE WARMERS
WHI to Lower Warmer
BLK to Terminal Block 
or Tank Heater Switch
Terminal #1 (See Chart 
Below)
Connect wire to Terminal #1 as follows:
Lower Warmer ..................................................... WHI/RED
One Upper Warmer (Rear) ............................................ VIO
Two Upper or Side Warmers 
(Front) ...................................................................BRN/BLK
(Rear) ............................................................................ VIO