Honeywell Bypass Flow Through Humidifier with Water Saving Technology (HE280) Installationsanleitung

Seite von 40
HE240, HE280 HUMIDIFIER AND INSTALLATION KIT
69-2686EF—01
12 
3. Insert the black rubber grommet into 
the duct hole.
4. Connect the tubing to the tubing fit-
ting elbow and insert the tubing fit-
ting elbow into the black rubber 
grommet.
5. Connect the other end of the tubing 
to the applicable pressure connec-
tion on the switch.
a. If the humidifier is installed on the 
supply duct (as is recom-
mended), the tube that inserts 
into the humidifier needs to be 
attached to the black port, and 
the tube that runs to the return 
duct needs to be attached to the 
gray port.
b. If the humidifier is installed on the 
return duct, the tube that inserts 
into the humidifier needs to be 
attached to the gray port, and the 
tube that runs to the supply duct 
needs to be attached to the black 
port.
Fig. 12. Installing the pressure switch 
tubing.
6. You may cut the tubing to fit the connection length between the elbow fitting and 
switch. It is also recommended to secure the hose to existing structures to avoid 
accidental disconnection.
M33326
69-2686EF_A.book  Page 12  Friday, March 9, 2012  11:37 AM