Honeywell RTH8500D Installationsanleitung

Seite von 60
Advanced Installation Guide
69-2219EF—03 24
Troubleshooting
SETUP
WIRING
ASSIST
ANCE
TROUBLESHOO
TING
If you have difficulty with your thermostat, please try 
the following suggestions.  
Most problems can be corrected quickly and easily.
Display is blank  •  Make sure fresh AAA alkaline 
batteries are properly installed 
(see page 7).
Cannot change 
system setting 
to Cool
•  Check Function 0170: System 
Type to make sure it is set to 
match your heating and cooling 
equipment (see page 16).
Fan does not 
turn on when 
heat is required
•  Check Function 0180: Heating 
Fan Control to make sure it is set 
to match your heating equipment 
(see page 17).
“Wait” appears 
on the screen
•  Compressor protection feature is 
engaged. Wait 5 minutes for the 
system to restart safely, without 
damage to the compressor.
Heat pump 
issues cool air 
in heat mode, or 
warm air in cool 
mode
•  Check Function 0190: Heat Pump 
Changeover Valve to make sure 
it is properly configured for your 
system (see page 17).