HE360 HUMIDIFIER AND INSTALLATION KIT
5
69-2631ES—03
Locating Closest Floor Drain 
• Select location with access to a floor drain to provide drainage for air conditioner 
condensation and humidifier drainage.
• If you do not have a drain available, we recommend that you install the Honeywell 
Whole House Drum or Disk Humidifier. Make sure that the 10 ft (3.1m) of drain 
tubing is adequate to reach from the humidifier drain connection to the floor drain. 
Selecting Location for Humidistat
• Select a location for the humidistat on the return plenum or on the wall in the living 
space. 
— Mounting on the return plenum is the easiest installation for the control wiring 
circuit.
For return duct mounting, the humidistat should be mounted upstream from the 
humidifier or bypass so that it is properly sensing the relative humidity of the living 
space. Locate the control at least 8 in. (203 mm) upstream from the humidifier in the 
return air duct. (See Fig 2.)
Fig. 2. Selecting duct location for humidistat.
Locating Closest 120V Electrical Outlet
• Select location with access to an outlet. If not available, contact an electrician to 
have one installed.
• Make sure that the humidifier cord is adequate to reach from the humidifier to the 
outlet.
• Make sure that the 20 ft (6.2m) of thermostat wire is adequate to reach from the 
humidifier solenoid, to the pressure switch, to the humidistat. 
Installing the Humidifier
WARNING
Hazardous Voltage 
Can cause personal injury or equipment damage.
Do not cut or drill into any air conditioning or electrical accessory.
ALTERNATE LOCATION
RETURN 
AIR
RETURN 
AIR
6 in. (152 mm) 
MINIMUM
15 in. (381 mm) 
MINIMUM
BEST 
LOCATION
RETURN AIR DUCT
M12831