Honeywell DR65 Техническое Руководство

Seite von 2
TrueDRY™ DR65
Ventilating Dehumidification System
SPECIFICATION DATA
68-3079-01
DR65 Capacities and Performance
Part Number: 
DR65
Blower: 
160 CFM @ 0.0 in. WG 
 
100 CFM @ 0.6 in. WG
Supply Voltage: 
120 VAC; 60 Hz.
Amps: 
5.2 A
Power transformer 
to R/C terminals:  24 VAC, 0.85A
Energy  
performance: 
2.22 liters (4.7 pints) per  
 
kilowatt hour (KWH)
Refrigerant: 
R-410A
Operating Temp Range 
(outside cabinet):  34 – 135 ºF (1.1 – 57.2 ºC)
Capacity: 
 
21 pints/day (60 ºF [15.6 ºC], 60 %RH) 
42 pints/day (70 ºF [21.1 ºC], 60 %RH) 
65 pints/day (80 ºF [26.7 ºC], 60 %RH)
Coverage: 
Up to 1800 sq. ft.
Duct Connections:  8 in. Round Inlet 
 
8 in. Round Outlet 
 
(ABS Plastic)
Filter Efficiency: 
Standard MERV-11
Drain Connection:  3/4 in. threaded female NPT, 
 
with attached 3/4 in. threaded 
 
male NPT
Dimensions (See Fig. 1): 
 
Width: 
12 in.  
Height: 
12 in. 
Length: 
28-1/2 in. (with collars) 
Weight: 
55 lbs (25 Kg)
Shipping Specs 
  
Width: 
15 in.  
Height: 
16 in. 
Length: 
31 in. (with collars) 
Weight: 
65 lbs (30 Kg)
Optional Parts 
 
Compressor overload: 
 
50049537-001 
Compressor relay 
      DPDT 24 VAC, 30A:   
50049537-002 
Run capacitor, 35 MFD:   
50049537-003 
8-in. Duct Collar: 
 
 
50049537-004 
Filter: 
 
 
50049537-005 
Fan: 
 
 
50033205-004 
Fan relay, SPDT, 24 VAC, 15A: 
50035445-011 
Transformer 120/24 VAC, 40VA: 
50035445-013
ETL Listed. Energy Star Rated. Conforms to UL 
Std. 474.
For more information call 1-800-468-1502 or 
visit our website at customer.honeywell.com.
The Honeywell TrueDRY DR65 ensures the home is maintained at proper 
humidity levels through its high performance and efficiency.
•  Remove up to 65 pints (30.8 L) of water per day from the indoor air
•  LED light interface
•  No additional wiring to an external control
•  Air Filtration
Dehumidification
The TrueDRY DR65 dehumidifier utilizes refrigeration and internal air cir-
culation to cool the incoming air stream below its dew point. This cooled 
and drier air is used to pre-cool the incoming air stream resulting in a 
significant increase in overall efficiency.
After helping to cool the incoming air, the processed air is reheated by 
passing through the condenser coil. The heat removed by the evapora-
tor coil is returned to the air stream, resulting in an overall temperature 
increase to the processed air. 
The TrueDRY DR65 is controlled by a variety of 24 volt remote wired con-
trols.
LED light interface
Feedback on operation and maintenance provided via intuitive on-board 
LED light interface.
No additional wiring to an external control
Built-in humidity control requires no additional writing to an external con-
trol. Just plug in and go! Choice of external control options also available
for centrally ducted control
Air Filtration
The TrueDRY DR65 includes air filtration to keep the DR65’s condenser 
coils clean. A MERV-11 media filter is standard.
Dimensions:
1 in. (D) x 9 in. (H) x 11 in. (W)
Fig. 1. Dimensions in in. (mm).
M29763
28-1/2 (724)
12 (305)
12
(305)
8 INCH (203)
DIAMETER