5-7
5. Setting of alarm
Set operation when alarm occurs.
The following screen is displayed if pressing the “ENTER” button with the blinking indication placed at the
“5.ALARM SET” by pressing the “MOVE” button on the main menu screen: 
- The blinking character moves if pressing “     ”, “     ” button.
- The setting value is changed if pressing “      ”, “      ” button. 
HOLD TIME   :  00 ~ 30 (MIN)
00 ~ 59 (SEC)
✴ The 00 MIN 00 SEC means a manual mode (perform operation for the time the alarm input enters into).
REC TYPE: NOR 
↔ TL V
• Set a record mode when alarm occurs. 
ALARM INPUT: OFF 
↔ N.O ↔ N.C ↔OFF
• Set according to the output of alarm sensor connected to the alarm input terminal on the rear side of this unit. 
• OFF: When no alarm input exists.
• N.O: When alarm input is ACTIVE LOW.
• N.C: When alarm input is ACTIVE HIGH.
- The changed setting value is stored if pressing the “SET” button and you can return to the main menu. 
6. Setting of motion 
Set motion detection and operation.
The following screen is displayed if pressing the “ENTER” button with the blinking indication placed at the
“6.MOTION SET” by pressing the “MOVE” button on the main menu screen: 
[ALARM SET]
HOLD TIME
01 MIN
00 SEC
REC TYPE
NOR
ALARM INPUT OFF
[MOTION SET]
SENSITIVITY
OFF
AREA SET
CH1...
MOTION OUT
OFF
LIST UPDATE
OFF
BUZZER
OFF
SDM-160(gb)00255  6/30/05 11:42 AM  Page 5-7