Ducting requirements
No. of 90° elbows
Weather hood type
4” (10 .16 cm)
2.5” (6.35 cm)
Recommended
Use only for short-run installation
Rigid
Metallic Flexible*
Rigid
Metallic Flexible*
0
24.4 m (80 ft.)
12.4 m (41 ft.)
22.6 m (74 ft.)
10.1 m (33 ft.)
1
20.7 m (68 ft.)
11.2 m (37 ft.)
18.9 m (62 ft.)
8.8 m (29 ft.)
2
17.4 m (57 ft.)
10.1 m (33 ft.)
15.5 m (51 ft.)
7.6 m (25 ft.)
3
14.3 m (47 ft.)
9.0 m (29 ft.)
12.5 m (41 ft.)
6.5 m (21 ft.)
* Do not use non-metallic flexible ducts.
• 
Use a 4 inch (10.2 cm) diameter rigid aluminum or rigid galvanized steel duct.
• 
Do not use a smaller duct.
• 
Ducts larger than 4 inches (10.2 cm) in diameter can result in increased accumulation of lint.
• 
Lint should be removed regularly.
• 
If a flexible metal duct must be used, use the type with a stiff sheet metal wall. Do not use a flexible duct with 
a thin foil wall. A serious blockage can result if the flexible metal duct is bent too sharply.
• 
Never install any type of flexible duct in walls, ceilings, or other concealed spaces.
• 
Keep the exhaust duct as straight and short as possible.
• 
Secure joints with duct tape. Do not use screws.
• 
Plastic flexible ducts can kink, sag, be punctured, reduce airflow, extend drying times, and affect the dryer 
operation.
• 
Exhaust systems longer than recommended can extend drying times, affect machine operations, and collect 
lint.
• 
The exhaust duct should end with an exhaust hood with a swing-out damper to prevent back drafts and 
entry of wildlife. Never use an exhaust hood with a magnetic damper.
• 
The hood should have at least 12 inches (30.5 cm) of clearance between the bottom of the hood and the 
ground or other obstruction. The hood opening should point down.
• 
Never install a screen over the exhaust outlet.
• 
To avoid lint buildup, do not exhaust the dryer directly into a window well. Do not exhaust under a house or 
porch.
• 
If the exhaust duct must run through an unheated area, the duct should be insulated and slope slightly down 
towards the exhaust hood to reduce condensation and lint buildup.
• 
Inspect and clean the interior of the exhaust system at least once a year. Unplug the power cord before 
cleaning.
• 
Check frequently to make sure the exhaust hood damper opens and closes freely.
• 
Check once per month, and clean at least once per year. Note: If your clothes are not getting dry, then check 
the duct for obstructions.
• 
Do not exhaust the dryer into a wall, ceiling, crawl space, or concealed space of a building, gas vent, or any 
other common duct or chimney. This could create a fire hazard from the lint expelled by the dryer.