Samsung ASV24PUQN Benutzerhandbuch

Seite von 41
29
ENGLISH
2 .  Open the front grille.
3 .  Remove the screw securing the connector cover.
4 .  Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals.  
(Refer to the picture below) 
5 .  Pass the other end of the cable through the 65mm hole in the wall.
6 .  Close the connector cover by tightening the screw carefully.
7 .  Close the front grille.
8 .  Remove the terminal board cover on the side of the outdoor unit.
9.  Connect the cables to the terminals as seen in the picture.
•   Each wire is labeled with the corresponding terminal number.
Indoor unit
Outdoor unit


18/24


10/13
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
•  Also circular terminal must be matched with screw size in terminal bl ck.
•  After connecting the cables, make sure terminal numbers on the indoor/o
o
utdoor unit matches.
10.  Connect the grounding conductor to the grounding terminals.  
11.  Close the terminal board cover by tightening the screw carefully. 
•   In Russia and Europe, consult with the supply authority to determine the supply system impedance before 
installation.
•   Connect the wires according to color codes, referring to the wiring diagram.
•   The power cable and the interconnection cable should be selected according to the 
 in page 28.
F1 F2
F1 F2
F2
F1
*
1.  Extend the assembly cable if necessary.
•   Do not connect two or more 
 cables to extend the length.  
It may cause 
 
 
When you install the unit, make 
 refrigerant connections and then electrical connections. 
Connect the air conditioner to grounding system before performing the electrical connection.  
If unit is uninstalled, 
 disconnect electrical cables, then refrigerant connections.
If the outdoor unit is more than 5 meters away from the indoor unit, you must extend the cable.  
The maximum length of the cable is  15(** 10/13 ** )/ 30( 18/24      ) meters.
•   For the terminal block wiring, use a wire with a ring terminal socket only.
ng work.
CAUTION
The terminal socket
or there is a space between the screw
and the ring terminal.
is upside down.
 There must be no space between the terminal and the screw when connected.
**
**