Fixing the indoor unit in place
Insulation
Pipes
'X' mm
Rubber leg
'Y
' mm
Perform the following work on the area where gas leak test was done priory .
After checking for gas leaks in the system, insulate the pipe, hose and cables . 
Then place the indoor unit on the installation plate .
1.  To minimise condensation problems, wrap foam insulation (as shown in the 
figure) on a part without insulation on the end of the pipes.
2.  Wind the pipe, assembly cable and drain hose with vinyl tape. 
3.  Place the bundle (the pipe, assembly cable and drain hose) in the lower part 
of the indoor unit carefully so it does not project from the rear of the indoor 
unit.
4.  Hook the indoor unit to the installation plate and move the unit to the right 
and left until it is securely in place.
•   Make sure pipe does not move when you install the indoor unit on
an installation plate.
5.  Wrap the rest of the pipe with vinyl tape.
6.  attach the pipe to the wall using clamps (optional).
Install at the outdoor unit on  stable base to help avoid the generation of noise and vibration, 
especially when installing the unit close to a neighbor. 
If you install the outdoor unit in a place exposed to strong winds or at a height, fix it with 
appropriate support (wall or ground).
1.  Place the outdoor unit as indicated on the top of the unit to let the discharged air out 
properly.  
2.  Fix the outdoor unit with appropriate support using anchor bolts.  
3.  If the outdoor unit is exposed to strong winds, install shield plates around the outdoor 
unit so that the fan can operate correctly.
Installation 
plate
Connecting wires
Connecting 
pipes
Vinyl tape
Drain hose
Fixing the outdoor unit in place
Model
X
Y
✴✴
12✴✴
538
290
✴✴
18/24✴✴
660
340
•   Ensure the wall will be able to support the weight of the rack and
outdoor unit;
•   Install the rack close to the column as much as possible;
•   Install proper grommet in order to help reduce noise and residual
vibration transferred by outdoor unit towards wall.
Outdoor unit installed on the wall by rack
Soft rubber designed to cut off 
vibration from rack to wall.  
(not supplied with product)
Designed to cut off residual vibration 
from outdoor unit to rack.  
(not supplied with product)
•  Secure the rubber leg to help prevent the generation of noise and vibration.