No.
Baud Rate(BPS)
SW2-#5
SW2-#6
1
 2,400
ON
ON
2
 4,800
ON
OFF
3
 9,600
OFF
OFF
4
19,200
OFF
ON
Function
 ON
OFF
SW2- #7
Transfer Mode Switch
RS-422(4Wire)
RS-485(2Wire)
Function
 ON
OFF
SW2- #8
Response Mode Switch
Response
No Response
Select the transfer speed of a selected communication protocol.
Select a communication method for the camera.
Select a communication response method for the camera and controller: Response or No 
Response.
• 
Baud Rate Settings
• 
Communication Method Settings
• 
Communication Response Settings
Camera Input Position
SW2- #10
SW2- #11
Termination of Longest Path
ON
ON
On the Path
OFF
OFF
Backup Function
SW2- #9
SW2- #12
Backup(IB→D)
OFF
OFF
Backup(D→IB)
ON
OFF
Backup Disable
-
ON
To prevent the attenuation of communication signals between the camera and controller, 2 
cameras in a longest distance for the camera and controller communication loop must be 
set up with the termination settings.
These settings are useful when the camera or its install base are damaged or malfunctions 
occur. When replacing the camera or its install base, you can transfer existing presets and 
sequence information to the replacement using these settings.
- Backup(IB→D) :  Enables transferring the current camera's sequence information to a new 
camera.
- Backup(D→IB) :  Enables transferring the current camera's sequence information to a new 
install base.
*IB: Install base, D: Dome Camera
• 
Termination Settings
• 
Camera Backup Settings
•Touseathirdpartycontrollerwiththisproduct,pleasecontactourAfter-SalesServiceor
Technology Department.
•ADProtocolControlMethod
  - Input Camera OSD: 3+Auxiliary On
  - Output Camera OSD: 3+Auxiliary Off
  - Enter: IRIS Open
  - ESC: IRIS Close
•Formoreinformationabouttheprotocols,refertoourofficialwebsite.
Notes
To set up camera IDs, refer to the “Camera ID Chart” next.
Camera ID DIP Switch Settings (SW1)
Installing Your Camera
Installing Your Camera