To activate series recording, set each of the connected
HSR-X200/X200P units as follows with 4.
RECORDING CONDITIONS SET of MAIN MENU
1.
For details on menu operations, see “Menu Operations” on
page 17(GB).
          <RECORDING CONDITIONS SET>
   SERIES RECORDING          : OFF
   NORMAL RECORDING AREA
     OVERWRITE               : OFF
   ALARM RECORDING AREA
     OVERWRITE               : OFF
   REMAINING DISK WARNING    : 1%
Set SERIES RECORDING to ON.
Set OVERWRITE to OFF for both NORMAL
RECORDING AREA and ALARM RECORDING
AREA.
For details on OVERWRITE, see “Recording Area Settings”
on page 46(GB).
Notes
• Series recording cannot be performed if timer
recording has been specified.
Be sure that the TIMER button indicator is dark on
all the connected HSR-X200/X200P units.
• If the OVERWRITE function is set to ON on any of
the connected HSR-X200/X200P units, recording
will be continued on that unit.
To start series recording
Press the z REC button on the first HSR-X200/
X200P.
Multiplexer Connection and
Associated Settings
Connection example
Settings
Specify the type of the connected multiplexer with
2. VIDEO INPUT/PRE REVERSE of MAIN MENU
1.
For details on menu operations, see “Menu Operations” on
page 17(GB).
                <VIDEO INPUT>
      MULTIPLEXER         : NO USE
              <PRE REVERSE PLAY>
        PRE REVERSE PLAY TIME : 10 MIN
SONY: Sony-made multiplexer (YS-DX516, etc.)
OTHERS1: Sanyo-made multiplexer
OTHERS2: Multiplexer of other manufacturers,
including Dedicated Micro and Robot
NO USE: Not to use any multiplexer
PC CARD
MIC
AUDIO
IN
IN
OUT
OUT
LOOP OUT
IN
OUT
LOOP OUT
RS-232C
S-VIDEO
VIDEO
IN
IN
OUT
OUT
WARNING OUT
CLOCK
NON REC OUT
ALARM
RESET
FULL
ALARM
FULL
ON
RS485
TERMINATE
OFF
COM
COM
A
B
IN OUT
COM
COM
COM
COM
COM
REMOTE
RS485
SERIES
SW OUT
-
AC IN
VIDEO 
OUT
ALARM
COM 
+ OUT
SW OUT
+ COM
VIDEO
IN
ALARM
COM
+ IN
SW+ C
AL
VCR IN
VCR OUT
HSR-X200/X200P
Multiplexer
to an AC outlet