Sony HVR-1500 Benutzerhandbuch

Seite von 111
77
Menu Contents
  
Chap
te
r 7
  
Men
u
s
OVER DISP HOLD [> Hold OVER]: Determine whether or not 
to hold the OVER indication display on the audio level 
meters once the indications light.
*OFF [>> OFF]: Do not hold the OVER indication display.
ON (HOLD) [>> ON]: Hold the OVER indication display.
Note 
With ON selected, once the display is held it will remain held 
unless you change the setting to OFF.
LCD [> LCD]: Adjust LCD 
monitor image quality.
BACK LIGHT [>> BK Light]: 
Set backlighting 
brightness.
1 [>>> 1] to 12 [>>> 12]: Larger numerical values indicate 
higher brightness
Factory default setting: *6 [>>> 6]
GAMMA [>> GAMMA]: 
Adjust the slope of the 
gamma correction curve.
OFF [>>> OFF]: No adjustment
TYPE 1 [>>> Type1]: Set to Type 1.
*TYPE 2 [>>> Type2]: Set to Type 2.
ALARM [> ALARM]: Determine whether alarm messages are 
issued or not.
OFF [>> OFF]: Alarm messages are not issued.
*ON [>> ON]: Alarm messages are issued.
REF ALARM [> REF ALARM]: Determine whether alarm 
messages related to reference video signal are issued or 
not.
OFF [>> OFF]: Alarm messages are not issued.
*ON (LIMITED) [>> ON (Limit)]: Alarm messages are issued 
only during recording mode, EE mode, REC-pause mode, 
and EDIT mode.
ON [>> ON]: Alarm messages are issued.
TIME CODE [Time code]: Settings related to the timecode 
generator
Description of settings
TC MODE [> TC mode]: Determine the timecode to use: 
internal timecode using a preset initial value, regenerated 
internal timecode (locked to timecode read from tape), or 
external timecode.
*INT PRESET [>> PRESET]: Use internal timecode with a 
preset initial value.
INT REGEN [>> REGEN]: Use internal timecode locked to 
timecode read from tape.
EXT REGEN [>> EXT]: Use external timecode selected as 
follows.
• When TC is selected
External timecode input to the TC IN connector
However, if SDI input is selected, in order to support 
embedded timecode the synchronization priority 
sequence is as follows.
1
 LTC (RP188) embedded in the SDI input
2
 An Input to the TC IN connector
• When VITC is selected
The VITC timecode present in the input video signal.
RUN MODE [> RUN mode]: Select the advancement (RUN) 
mode of the timecode generator.
*FREE RUN [>> FREE RUN]: Timecode generator keeps 
running.
REC RUN [>> REC RUN]: Timecode generator runs only while 
recording.
Note 
Set to FREE RUN when carrying out editing with an editing 
control unit. With the REC RUN setting, editing will not be 
carried out correctly.
DF MODE [> DF mode]: Select whether the timecode 
generator and time counter operate in drop frame mode or 
non-drop frame mode.
Normally select drop frame mode to keep in 
synchronization with real time. The non-drop frame mode 
is useful for example when using computer graphics, and 
working on a frame count basis.
Note 
Displayed only when the system frequency is set to 60i.
*ON (DF) [>> ON (DF)]: Drop frame mode
OFF (NDF) [>> OFF (NDF)]: Non-drop frame mode
DISPLAY CONTROL [Display]: Settings related to monitor 
display and indicators
Description of settings