Miscellaneous
Error codes displayed during operation stage
(The ERROR LED lights when an error occurs during operation.)
(The ERROR LED lights when an error occurs during operation.)
* A degradation in system performance will occur when a read error occurs while the
resync operation is in progress.
Error
code
code
STATUS
LED
LED
ERROR
LED
LED
Possible Cause
1
On
Critical temperature
2
On
CPU fan failure
3
On
Power supply fan failure
4
On
Voltage power supply
failure
failure
5
On
Hard disk drive fan 1 failure
6
On
Hard disk drive fan 2 failure
7
On
Hard disk drive is damaged.
8
On
Reserved for future use
9
On
Reserved for future use
A
On
Reserved for future use
B
On
Reserved for future use
C
On
Application functioning
failure.
failure.
D
On
Reserved for future use
E
On
RAID data volume failure
F
On
Resync operation in RAID
data volume*