Sony MZ-R90 Handbuch

Seite von 56
46
System limitations
The recording system in your MiniDisc recorder is radically different from those used in 
cassette and DAT decks and is characterized by the limitations described below. Note, 
however, that these limitations are due to the inherent nature of the MD recording system 
itself and not to mechanical causes.
Symptom
Cause
“TR FULL” appears 
even before the disc 
has reached the 
maximum recording 
time (60, 74, or 80 
minutes).
When 254 tracks have been recorded on the disc, “TR FULL” 
appears regardless of the total recorded time. More than 254 
tracks cannot be recorded on the disc. To continue recording, 
erase unnecessary tracks.
“TR FULL” appears 
even before the disc 
has reached the 
maximum track 
number or recording 
time.
Repeated recording and erasing may cause fragmentation and 
scattering of data. Although those scattered data can be read, 
each fragment is counted as a track. In this case, the number of 
tracks may reach 254 and further recording is not possible. To 
continue recording, erase unnecessary tracks.
Track marks cannot be 
erased.
The remaining 
recording time does 
not increase even after 
erasing numerous short 
tracks.
When the data of a track is fragmented, the track mark of a 
fragment under 12 seconds long cannot be erased. You cannot 
combine a track recorded in stereo and a track recorded in 
monaural; nor can you combine a track recorded with digital 
connection and a track recorded with analog connection.
Tracks of under 12 seconds in length are not counted and so 
erasing them may not lead to an increase in the recording time.
The total recorded time 
and the remaining time 
on the disc may not 
total the maximum 
recording time (60, 74, 
or 80 minutes).
Normally, recording is done in minimum units of approximately 
2 seconds. When recording is stopped, the last unit of recording 
always uses this unit of 2 seconds even if the actual recording is 
shorter. Likewise, when recording is restarted after the stop, the 
recorder will automatically insert a blank space amounting to 2 
seconds before the next recording. (This is to prevent accidental 
erasing of a previous track whenever a new recording is started). 
Therefore, the actual recording time will decrease whenever a 
recording is stopped; a maximum of 6 seconds compared to the 
potential recording time for each stop.
The edited tracks may 
exhibit sound dropout 
during search 
operations.
The fragmentation of data may cause sound dropout while 
searching because the tracks are played in higher speed than 
normal playback.