Sony SNCDH110W Benutzerhandbuch

Seite von 132
CGI Command Manual   
67 
11.9 Serial 
Parameter 
Value 
InqParm 
SetCGI 
Ver 
Note 
SerType 
SNC-RH124/164, SNC-RS44/46/84/86: 
"tcpip"/"visca"/"pelco-d" 
SNT-EX101/101E/104/154: 
"normal"/"tcpip" 
serial 
serial.cgi 
1.00 
 
SerTcpPort 
"1024"to"65535" 
serial 
serial.cgi 
1.00 
 
SerBaudRate 
"2"to"7" 
serial 
serial.cgi 
1.00 
2:1200, 3: 2400, 4:4800, 5:9600, 6:19200, 7:38400 (bps) 
SerCharLen 
"7"/"8" 
serial 
serial.cgi 
1.00 
 
SerParityBit 
"none"/"odd"/"even" 
serial 
serial.cgi 
1.00 
 
SerStopBit 
"1"/"2" 
serial 
serial.cgi 
1.00 
 
SerStandard 
SNC-RH124/164, SNC-RS44/46/84/86: 
"rs232c"/"rs485"/"rs422"/"rs485fd" 
SNT-EX101/101E: "rs485"/"rs422" 
SN-EX104/154: "rs485" 
serial 
serial.cgi 
1.00 
 
SerProtocol 
"pelco-d"/"ad"/"pelco-p"/"bosch"/ 
"vicon"/"panasonic"/"ge"/"visca" 
serial 
serial.cgi 
1.2 
 
SerTermination 
"on"/"off" 
serial 
serial.cgi 
1.00 
 
SerDstCamId 
"1"to"256" 
serial 
serial.cgi 
1.00 
 
SerSrcCamId 
"1"to"256" 
serial 
serial.cgi 
1.00 
 
 The command which can't be used in each model is shown in the following table. 
Model name 
Unsupported command (Serial) 
SNC-RH124/164 
SerDstCamId, SerProtocol 
SNC-RS44/46/84/86 
SerDstCamId, SerProtocol 
SNT-EX101/101E 
SerSrcCamId, SerTermination