Figure 9 shows each testing point for the PA section from the Cell Transmitter Test Path 
table on page 10. Always attach a 20dB pad (11881-60001) when probing with an 
HP85024A high frequency probe.
Figure 9: (Top) PWB. (Bottom left) A zoomed view of the testing points on the PA section. 
(Bottom right) A zoomed view of the PA section with part numbers.
Tx AGC Tuning
Tx power versus IF/RF PDM can be verified against FlaLi specification limits. Make sure 
that the PA is set in high gain mode (GenIO bits 10, 13, and 12 are set to H).
Tx AGC Tuning
Tx Tuning 
AGC Step
Tx AGC 
PDM 
Value
Target 
Power
Low Limit
High Limit
Tx AGC (0)
308
-46
-55
-37
Tx AGC (1)
130
-24
-34
-14
Tx AGC (2)
85
-15
-25
-6
Tx AGC (3)
51
-4.5
-14
5
Tx AGC (4)
19
2.5
-7
12
Tx AGC (5)
-5
6
-3
15