Nokia 3105 Servicehandbuch

Seite von 44
CCS Technical Documentation
Troubleshooting - RF
RH-48
Issue 1 11/2003
© 2003 Nokia Corporation         Confidential
Page 17
Cell IF/RF AGC and PA Control
The following Cell CDMA Channel 384 (Skyworks PA) table illustrates the PDM values and their 
typical values for the IF AGC, RF AGC Jedi Pout, gain steps, and the PA VCC levels.  This table also 
shows the typical power output at the RF connector.
Cell Power Detector
The following tables illustrate the measurements required for troubleshooting the cell 
power detector.
Cell CDMA Channel 384 (Skyworks PA)
Tx RF AGC
Tx IF AGC
Jedi Po
PA Gain 
Step
PA Vcc
Conn 
RF 
Pout
PDM Typical 
Value
Test 
Point
PDM
Typical 
Value
Test 
Point
Typical 
Value
Test 
Point
Gen 
IO 
12
Gen 
IO 
13
Typical 
Value
Test 
Point
PA 
Gain
-290
0.45
Bot-
tom 
C606
-290
0.45
Top 
C605
3
pin  1 
Z601
H
H
3.47
C806
DM
25
-196
0.59
-196
0.59
-2
H
H
3.61
28
20
-95
0.75
-95
0.75
-9.2
H
H
3.67
28
13.2
-95
0.75
-95
0.75
-9.2
H
L
1.2
26
11
-48
0.83
-48
0.83
-13
H
L
1.2
25.8
7
-48
0.83
-48
0.83
-13
L
L
0.82
24.5
6
17
0.93
17
0.93
-19
L
L
0.82
0
80
1.04
80
1.04
-29
L
L
0.82
-10
120
1.11
120
1.11
-39
L
L
0.82
-20
168
1.19
168
1.19
-49
L
L
0.82
-30
249
1.32
249
1.32
-59
L
L
0.82
-40
324
1.49
324
1.49
-69
L
L
0.82
-50
Cell Power Setup:
Mode
Tx
Rx
Band
Chnn
Rho
Local
On
On
CELL
384
On
Input Chnn
Tx Freq
Rx Freq
384
836.52
881.52