Nokia 3105 Servicehandbuch
CCS Technical Documentation
System Module
RH-48
Issue 1 11/2003 Confidential ©
2003 Nokia Corporation
Page 15
Figure 4: Mechanical dimensions and signals of Tomahawk bottom connectors
An accessory is detected by the ACI-line. All accessories will generate interrupt while
inserted or removed from the phones Tomahawk system connector. Insertion of an acces-
sory will generate HEADINT interrupt by pulling ACI line down. Vout is enabled by UPP.
The MBUS line is connected to HEADINT line. If HEADINT interrupt from low to high
transition occurs within 20msec a more advanced accessory is connected else a basic
headset is connected.
inserted or removed from the phones Tomahawk system connector. Insertion of an acces-
sory will generate HEADINT interrupt by pulling ACI line down. Vout is enabled by UPP.
The MBUS line is connected to HEADINT line. If HEADINT interrupt from low to high
transition occurs within 20msec a more advanced accessory is connected else a basic
headset is connected.
Charger IF
Introduction
The charger connection is implemented through the bottom connector. DCT-4 bottom
connector supports charging with both plug chargers and desktop stand chargers.
connector supports charging with both plug chargers and desktop stand chargers.
There are three signals for charging. Charger gnd pin is used for both desktop and for
plug chargers as well as charger voltage. PWM control line, which is needed for 3-wire
chargers, is connected directly to gnd in module PWB so the RH-48 engine doesn't pro-
vide any PWM control to chargers. Charging controlling is done inside UEM by switching
UEM internal charger switch on/off.
plug chargers as well as charger voltage. PWM control line, which is needed for 3-wire
chargers, is connected directly to gnd in module PWB so the RH-48 engine doesn't pro-
vide any PWM control to chargers. Charging controlling is done inside UEM by switching
UEM internal charger switch on/off.
Interface
The fuse (F100) protects from high currents (e.g. , when broken or pirate chargers are
used). L100 protects engine from RF noises that may occur in charging cable. V100 pro-
tects UEM ASIC from reverse-polarity charging and from high charging voltage. C106 is
also used for ESD and EMC protection.
used). L100 protects engine from RF noises that may occur in charging cable. V100 pro-
tects UEM ASIC from reverse-polarity charging and from high charging voltage. C106 is
also used for ESD and EMC protection.
PWB
5.70
3.50
XM
IC
N
XM
IC
P
AC
I
21.20
V
out
6.55
US
B
Vbus
U
S
B D-
/
Fbus
T
X
US
B D+
/
F
b
u
s RX
DAT
A
GN
D
2.70
1.00
S
h
ie
ld
ing GND
HSE
A
R
P
HSE
A
R
N
5.40
0.30
Metal
shielding
shielding
Shielding GN
D
HS
EAR R
P
H
S
E
A
R R N
9.50
6.50
Ch
ar
g
e GN
D