Exhaust Requirements
70269701
38
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table 5 
Duct
Station
25 and 30 Pound
T30 and 35 Pound
6 in. (152 mm) Duct
8 in. (203 mm) Duct
2A
2B
2A
2B
A
7 in. (178 mm)
10 in. (254 mm)
9 in. (229 mm)
12 in. (305 mm)
B
10 in. (254 mm)
15 in. (381 mm)
12 in. (305 mm)
17 in. (432 mm)
C
12 in. (305 mm)
18 in. (457 mm)
15 in. (381 mm)
22 in. (559 mm)
D
14 in. (356 mm)
20 in. (508 mm)
17 in. (432 mm)
25 in. (635 mm)
E
16 in. (406 mm)
23 in. (584 mm)
19 in. (483 mm)
27 in. (686 mm)
F
18 in. (457 mm)
26 in. (660 mm)
21 in. (533 mm)
30 in. (762 mm)
G
19 in. (483 mm)
27 in. (686 mm)
23 in. (584 mm)
33 in. (838 mm)
H
20 in. (508 mm)
29 in. (737 mm)
24 in. (610 mm)
34 in. (864 mm)
I
22 in. (559 mm)
32 in. (813 mm)
26 in. (660 mm)
37 in. (940 mm)
J
23 in. (584 mm)
33 in. (838 mm)
27 in. (686 mm)
39 in. (991 mm)
K
24 in. (610 mm)
34 in. (864 mm)
28 in. (711 mm)
40 in. (1016 mm)
L
25 in. (635 mm)
36 in. (914 mm)
30 in. (762 mm)
43 in. (1092 mm)