Honeywell TH3210D Benutzerhandbuch

Seite von 16
Installation Guide
8
10
0
Test
10
20
30
70
Heating system
Emergency heat
Cooling system
Thermostat
information
(for reference only)
0
Compressor and fan turn off.
1
Compressor and fan turn on.
2
Auxiliary heat turns on.
0
Heat and fan turn off.
1
Heat and fan turn on.
2
Auxiliary heat turns on.
0
Compressor and fan turn off.
1
Compressor and fan turn on.
71 Software revision number (major revisions)
72 Software revision number (minor revisions)
73 Configuration identification code (major)
74 Configuration identification code (minor)
75 Production configuration date code (week)
76 Production configuration date code (year)
System Test
System Status 
Installer system test
CAUTION: EQUIPMENT DAMAGE HAZARD
Compressor protection (minimum off time) is bypassed during testing. To prevent
equipment damage, avoid cycling the compressor quickly.
System switch
System test
number
System status
Follow the procedure below to test the heating and cooling system.
1
Set 
S
SY
YS
ST
TE
EM
M
switch to Heat.
2
Press 
to turn on and check systems (see table, below).
3
Press 
until systems turn off.
4
Set 
S
SY
YS
ST
TE
EM
M
switch to Em Heat and repeat steps 2-3 above.
5
Set 
S
SY
YS
ST
TE
EM
M
switch to Cool and repeat steps 2-3 above.
5
Press and hold
to terminate test at any time.