Troubleshooting Tips
If . . .
Then . . .
Key to the right of the 
Screen key is blank.
Verify that this key remains blank unless you 
set the Furnace Filter Change Reminder. See 
Installer Setup Number 0500 in Step 11.
Display is blank.
Check that fresh AAA alkaline batteries are 
installed as marked on the thermostat.
Temperature settings 
do not change.
Check that the temperature settings are:
• Heating 40°F to 90°F(4.5°C to 32°C).
• Cooling 50°F to 99°F (10°C to 37°C).
Heating system does 
not turn on.
• Set the system to Heat by pressing the 
System key.
• Check the heat temperature setting to be 
sure it is set above the room temperature 
and “Heat On” shows solidly in the display.
• Check the circuit breaker to be sure it is 
not tripped.
• Check power switch at heating and/or 
cooling system to be sure it is on.
• Check the furnace door to be sure it is 
closed securely.
• Wait five minutes for the heating system to 
respond.
• If all of this was checked, contact your 
local heating and cooling contractor.
Cooling system does 
not turn on.
• Set the system to Cool by pressing the 
System key.
• Check the cool temperature setting to be 
sure it is set below the room temperature 
and “Cool On” shows solidly in the display.
• Check the circuit breaker to be sure it is 
not tripped.
• Check the power switch at the heating 
and/or cooling system to be sure it is on.
• Check the furnace door to be sure it is 
closed securely.
• Wait five minutes for the cooling system to 
respond.
• If all of this was checked, contact your 
local heating and cooling contractor.