Honeywell CT3595 Benutzerhandbuch
69-1199—4
8
STEP 4. WIRE WALLPLATE TERMINALS
IMPORTANT
All wiring must comply with local codes and ordinances. If unsure about household wiring procedures, call
your local heating/air-conditioning contractor.
your local heating/air-conditioning contractor.
Refer to the labels you placed on the wires when you removed the
old thermostat (see illustration).
old thermostat (see illustration).
q
Match the letter of your old thermostat wire with the
corresponding terminal letter on your new thermostat. Refer to
Table 2.
corresponding terminal letter on your new thermostat. Refer to
Table 2.
q
Remove the factory-installed jumper connecting terminals R and
RC if wires are connected to both of those terminals.
RC if wires are connected to both of those terminals.
q
For wiring diagrams, if needed, see pages 22-23.
q
Loosen the terminal screws. Slip each wire beneath its matching
terminal. Wraparound and straight connections are both
acceptable, (see illustration). Tighten the terminals.
terminal. Wraparound and straight connections are both
acceptable, (see illustration). Tighten the terminals.
q
Plug the hole in the wall with insulation to help prevent drafts
from adversely affecting thermostat operation.
from adversely affecting thermostat operation.
M16425
R
W
Y
G
M4826
FOR WRAPAROUND
INSERTION STRIP
7/16 IN. (11 MM).
INSERTION STRIP
7/16 IN. (11 MM).
FOR STRAIGHT INSERTION
STRIP 5/16 IN. (8 MM).
STRIP 5/16 IN. (8 MM).