Honeywell chronotherm iv t8600d Benutzerhandbuch

Seite von 12
T8600D CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATS
9
69-1409—1
NOTE: You can view the number of days remaining at 
any time by pressing the i key three or four 
times. If more than one timer is active, all active 
timers show sequentially when pressing the 
key several times.
INSTALLER SYSTEM TEST
Use the Installer System Test to check the thermostat 
operation. Refer to Table 4 for a list of the available 
system tests.
CAUTION
Equipment Damage Hazard.  
Minimum compressor off-time is bypassed 
during Installer System Test.
Avoid cycling compressor quickly.
To start the system test:
Press and hold the increase   and decrease   keys at 
the same time until 10 appears. All segments of the 
display are displayed before the 10 appears. See Fig. 12 
and 13.
 
Fig. 12. LCD segments display.
Fig. 13. Test number display.
Refer to Table 5 for the directions and results of the 
specific tests.
NOTE: Press Time 
∆ to advance to the next test and 
Time 
∇ to go back to the previous test. Press 
Run Program to exit the system test
Table 4. Tests Available In Installer System Test.
Test 
Number
System Test Description
10-19
Heating equipment can be turned on and 
off.
30-39
Cooling equipment can be turned on and 
off.
40-49
Fan equipment can be turned on and off.
60  0 to
60  19
Keyboard keys test.
70-79
Thermostat information, including date 
code and software versions, is displayed.
M14559
Aux Ht
Set Day/Time
Set Program
Mon
Wake Leave Return
Sleep
Outdoor
Room
Filter
Wait
System
Fan
Em Heat
On
Auto
Off
Cool
Auto
AM
PM
Hold for
Heat
Cool
Repl Batt
Recovery
DST
Tue Wed Thu Fri Sat Sun
Days
Temporary Setting
Em Ht
M14612
Table 5. Installer System Test Options.
Keys to 
Press
Test 
Number
Description
Heating Equipment System Test
Time 
 
10
Enter heating equipment system test.
11
Heat comes on. When Installer Setup number 2 is 1; the system fan is also energized.
10
Heat and system fan turn off.
Cooling Equipment System Test
Time 
30
Change from heating to cooling equipment system test. 
31
Cool and system fan come on.
30
Cool and system fan turn off.
Fan Equipment System Test
Time 
40
Change from cooling to fan equipment system test.