FMI pfs (v)dvf36nh Benutzerhandbuch

Seite von 40
www.fmiproducts.com
125078-01B
26
trOUbLeShOOting
 WARNING: Turn off fireplace and let cool before servicing. Only 
a qualified service person should service and repair fireplace.
 CAUTION: Never use a wire, needle or similar object to clean 
pilot. This can damage pilot unit.
Note: All troubleshooting items are listed in order of operation.
pOSSIBLE CAUSE
1. No  gas  supply  or  shutoff 
valve is OFF
2. Air in gas line
3. Construction  debris  clog-
ging pilot orifice
4. Low gas pressure
5. Kinked pilot line
6. Control valve is not opening
7. No power to unit or ignition 
module  or  power  trans-
former is bad
REMEDY
1. Check to see if you have gas 
supply and that equipment 
shutoff valve is opened
2. Repeat  lighting  procedure 
several  times  to  purge  all 
air out of lines. If after re-
peated attempts appliance 
does not light, call for quali-
fied service and repair
3. Remove  debris  and  dirt, 
inspect and clean any other 
possible obstructions
4. Contact  your  gas  supplier 
to check pressure
5. Have a qualified technician 
replace pilot line
6. Replace control valve (Re-
fer  to  Replacement  Parts
page 36)
7. Check that main power is 
on and that all wire connec-
tions are made correctly to 
ignition model (see Wiring 
Diagram, page 29). Check 
for 24 VAC at the second-
ary side of transformer. If 24 
VAC is present and module 
does  not  operate,  have 
module  replaced.  Other-
wise  have  transformer  re-
placed
OBSERVED PROBLEM
Ignitor  will  not  spark  or  pilot 
will not light