Honeywell CT54 Benutzerhandbuch

Seite von 8
CT54 THERMOSTAT
3
69-1696EF
STEP 5. SET HEAT ANTICIPATOR 
ON NEW THERMOSTAT
1. Set the heat anticipator lever to the number that 
you recorded in Step 2. Remove Old Thermostat
sub-step 4 (see Fig. 7). 
Fig. 7. Heat anticipator on new thermostat.
2. If you could not find a heat anticipator setting on 
your old thermostat, use the setting listed in 
Table 1 for your type of heating system. 
Table 1. Heat Anticipator Setting.
3. Place the cover on the thermostat and turn the 
power back on. If the heating system runs too long 
to maintain a comfortable temperature, adjust heat 
anticipator lever clockwise one scale mark (see Fig. 
7). Do not adjust heat ancitipator below .3 Amps. If 
the heating system needs to run longer to maintain 
a comfortable temperature, adjust heat anticipator 
lever counterclockwise, in the direction of the arrow, 
one scale mark (see Fig. 7).
STEP 6. OPERATING NEW 
THERMOSTAT
1. Adjust the temperature setting lever to your desired 
setting. If it is too warm, lower the temperature set-
ting. If it is too cool, raise the temperature setting.
IF YOU HAVE A PROBLEM
Customer Assistance
Please read and follow the provided instructions for this 
thermostat. For additional information, go to 
www.honeywell.com/your home 
or call Honeywell 
Customer Care at 1-800-468-1502.
Before calling, please have the following information 
available:
• Thermostat model number and date code (refer to Fig. 
6 for the location of the model number and date code).
• Type of heating system (for example: gas or oil; warm 
air, hot water). 
Heating System
Heat Anticipator 
Setting (Amps)
Hot Water
.8
High Efficiency Warm Air (90% or 
better)
.8
Gas or Oil Warm Air
.4
Electric
.3
.18
.2
.25
.3
.9
.7
.5
.4
L
O NGER
M19650
PLACE FINGER
HERE TO MOVE
LEVER
HEAT ANTICIPATOR
.18
.2
.25
.3
.9
.7
.5
.4
L
O NGER
D
A
TE CODE
MODEL NO
.
THIS POINT
SHOULD ALIGN WITH
HEAT ANTICIPATOR
SETTING
If. . .
Then. . .
Heating system 
does not come on.
• Make sure the temperature 
setting is above the room 
temperature.
• Make sure the circuit breaker 
is not tripped and reset it if 
necessary.
• Make sure the power switch at 
the equipment is in the On 
position.
• Wait 5 minutes for the system 
to respond.
Heating system runs 
too long to maintain 
a comfortable 
temperature.
• Verify the thermostat is level.
• Adjust heat anticipator lever 
clockwise one scale mark (see 
Fig. 7). Do not adjust heat 
anticipator below .3 Amps.
Heating system 
needs to run longer 
to maintain a 
comfortable 
temperature.
• Verify the thermostat is level.
• Adjust heat anticipator lever 
counterclockwise, in the 
direction of the arrow, one 
scale mark (see Fig. 7).