Before Installing
Installation of this system must be made in accordance with
National Electrical Code Article 426 - Fixed Outdoor Electric
Deicing and Snow-Melting Equipment.
Install all wiring in accordance with all national and local codes
pertaining to outside wiring.
For installation under concrete only.
Do not install this system under tarmac or other hot-pour sur-
facing materials.
Do not incorporate any other outdoor electrical equipment in
any branch circuit which feeds this heating system. 
This system must be connected to an electrical branch circuit
incorporating a ground fault circuit interruper (GFCI) rated for
equipment protection.
Heating mats must never be run through or accross expansion
joints.
Do not run power leads, other electrical wiring or any other
material between the heating mats and the surfacing material.
Special care must be taken to ensure that expansion joints do
not extend into the heating elements. Elements which are
damaged are shock and fire hazards. If possible, order ele-
ments sized so that the expansion joints can be cut between
the elements and leave one inch (2.5 cm) between the ele-
ments.
WARNING: Ensure that adequate drainage is provided for
water runoff.