Chapter 6
Maintenance
2098.1190.72
- 6.1 -
E-3
1
Maintenance Intervals
The following maintenance work must be performed at regular intervals:
1.1
Maintenance of Subcontractor Products
Subcontractor products such as external air filters must be maintained in accordance with
the maintenance instructions from the respective manufacturer and for the respective prod-
uct. 
Maintenance interval
Task
Procedure described in:
2x per year
 Check the operating values (e.g. 
output power, control values, etc) 
1x per year
 Check and, if necessary, change 
the backup battery of the transmit-
ter control unit (R&S NetCCU800)
Chapter "Maintenance" in the 
R&S NetCCU800 manual
After 5 years and then 
1x per year
 Check whether the two rack fans 
make noises when in operation; 
replace them if necessary
Chapter "Service“ in this man-
ual
After 5 years and then 
1x per year
 Check whether the fans make 
noises when in operation; replace 
them if necessary
Chapter "Maintenance" in the 
exciter manual