Honeywell BOTAC01 Benutzerhandbuch

Seite von 32
Honeywell IdentIPoint Intelligent Smartcard Readers 
DI
 sw
it
ch
  ‐
S1
Position
Effect when “ON”
(Position Up)
1
RS485‐A pull up
2
RS485 termination
3
RS485‐B pull down
4
Reserve
Position
Effect when “ON”
(Position Up)
1
RS485‐A pull up
2
RS485 termination
3
RS485‐B pull down
4
Reserve
Switch
Description
S1
RS485 Termination Control DIP switch
S2
Initialization Button
S3
IOM Address set up DIP switch
S4
Cover tamper detection switch
Switch
Description
S1
RS485 Termination Control DIP switch
S2
Initialization Button
S3
IOM Address set up DIP switch
S4
Cover tamper detection switch
S2: Initialization 
Button
DI
 sw
it
ch
 S3
IO
M
 a
ddr
ess
Position
Description
1
Address value 1
2
Address value 2
3
Address value 4
4
Address value 8
5
Address value 16
6
Address value 32
7
Address value 64
8
For IOM setup, normally set to OFF
Position
Description
1
Address value 1
2
Address value 2
3
Address value 4
4
Address value 8
5
Address value 16
6
Address value 32
7
Address value 64
8
For IOM setup, normally set to OFF
S4: Cover tamper 
detection switch
 
 
Fig.17. IOM connections 
 
95-7771 
19