Bosch ISW-BIT1-HAX WLSN INSTALLATION F.01U.001.830 Benutzerhandbuch
Produktcode
F.01U.001.830
Mobile Operation
When removed from the docking station, the tool
automatically switches to mobile operating mode
wherein it is powered by its batteries and goes into a
sleep mode after a preset duration of inactivity. The
tool automatically wakes up from sleep mode
whenever a button is pressed.
automatically switches to mobile operating mode
wherein it is powered by its batteries and goes into a
sleep mode after a preset duration of inactivity. The
tool automatically wakes up from sleep mode
whenever a button is pressed.
Certifications and approvals
Listings and Approvals:
Complies with:
EN50131-1 Grade 2, Environmental class
II
Region
Certification
Europe
CE
1999/5/EC, IEC60950-1: 2001,
EN60950-1:2001 +A11:2004,
EN50130-4: 1996 +A1: 1998 +A2:
2003, EN61000-4-2: 1995 +A1: 1998
+A2: 2001, EN61000-4-3: 2002 +A1:
2003 +A2: 2005, EN61000-4-4: 1995
+A1: 2001 +A2: 2001, EN61000-4-5:
1995 +A1: 2001, EN61000-4-6: 1996
+A1: 2001 +A2: 2001 +A3: 2005,
EN61000-4-11: 1994 +A1: 2001,
EN55022/ANSI C63.4: 2003, ETSI EN
300 220-1 V1.3.1: 2000-09, ETSI EN
301 489-1 V1.4.1: 2002-08, ETSI EN
301 489-3 V1.4.1: 2002-08
Installation/configuration notes
Compatibility Information
The wLSN Installation Tool requires the wLSN Hub to
operate and provide installation information.
operate and provide installation information.
Mounting Considerations
The required region-specific transformers have 1.8 m
(6 ft) cords. Position the docking units near a wall
outlet in order to plug in the transformer.
(6 ft) cords. Position the docking units near a wall
outlet in order to plug in the transformer.
Notice
Refer to the wLSN Installation Tool Installation
Instructions (P/N: F01U008748) for instructions on
connecting the transformers to the docking
stations.
Refer to the wLSN Installation Tool Installation
Instructions (P/N: F01U008748) for instructions on
connecting the transformers to the docking
stations.
Mount the wall-mount docking station to an interior
wall and/or place the desktop docking station on a flat
surface. The docking stations must be protected from
weather elements such as rain or snow and from
accidental exposure to spills or leaks.
wall and/or place the desktop docking station on a flat
surface. The docking stations must be protected from
weather elements such as rain or snow and from
accidental exposure to spills or leaks.
Parts included
Quant.
Component
1
Installation tool
1
Transformer (region specific)
1
2
Docking stations (wall and desktop)
3
AAA (NiMH) batteries (P/N: 16556)
1
Hardware pack
1
Literature pack
1
Each installation tool is supplied with a region-
specific transformer designed to be wired to either of
the docking stations and to plug into the local
electrical outlet. Refer to the following for transformer
illustrations:
the docking stations and to plug into the local
electrical outlet. Refer to the following for transformer
illustrations:
European transformer (A) supplied with ISW-BIT1-HAX
United Kingdom transformer (B) supplied with ISW-
BIT1-HBX
BIT1-HBX
United States transformer (C) supplied with ISW-BIT1-
HCX
HCX
Technical specifications
Environmental Considerations
Environment:
Indoor, dry
EN50131-1:
Environmental Class II
Relative Humidity:
Up to 95%, non-condensing
Temperature (operating):
-10°C to +55°C (+14°F to +131°F)