Vigitron VI1516VPD Merkblatt
© Copyright 2009 Vigitron, Inc.
Technical Specification
*
Electrical
Input Voltage
110 VAC or 220 VAC, externally switch selectable
Input Current
4.8 A (110 VAC) / 2.4 A (220 VAC)
Camera Power
Voltage: Isolated class II, 24 VAC, off, 28 VAC
Rear panel switch selectable
Current: 1 A maximum per camera, 12 A maximum aggregated
Total power:
340 VA
Fault Protection
2 A glass fuse (front access) per camera
Video Format
NTSC, PAL, SECAM
Frequency
20 Hz to 10 MHz
CMRR 60
dB
Twisted Pair (UTP) 100 Ohms +/- 20%, 24 AWG minimum, Category 2-7
Diagnostics LEDs No load or shut down: 16 red LEDs, one per channel
Power present: 16 green LEDs, one per channel
Connectors
Camera connection: RJ-45 connector
Data: RJ-45 connector
Control room video: BNC
Transient Immunity
per ANSI 587 C62.41
TEL (+1) 858 - 484 - 5209 • FAX (+1) 858 - 484 - 1205
13906 Sparren Ave. San Diego, CA 92129, USA • info@vigitron.com • www.vigitron.com
13906 Sparren Ave. San Diego, CA 92129, USA • info@vigitron.com • www.vigitron.com
System Configuration
Ordering Information
PART No.
Description
Mechanical
Dimensions
1.75x17x12 in., 4.3x43x30.5 cm (HxWxL)
Weight
22 lb, 10 kg
Material
Steel sheet metal
Environmental
Humidity
0 to 95%, non-condensing
Temperature
Operating: -20°C to +50°C
Storage: -30°C to +70°C
Minimum Airflow
5 cft.
/min
Heat 1300
BTU/hour
Vi1516VPD 16-Ch Powered VPD Combiner-Receiver
Vi1508VPD 8-Ch Powered VPD Combiner-Receiver
*Specifications subject to change without notice.
1.75"
19"
Vi1516VPD
Video +
Video
Data
Video
Data
+
Power
Power +
Data
Power +
Power
Power +
Data
Power +
Power
Pin#
1
2
3
4
5
6
7
8
2
3
4
5
6
7
8
VPD
Camera Connections:
Camera -1
Camera -2
Camera -3
Camera -4
Camera -5
Camera -6
Camera -7
Camera -8
Camera -9
Camera -10
Camera -11 Camera -12
Camera -13 Camera -14
Camera -15 Camera -16
Data 1-4
Data 5-8
Data 9-12
Data 13-16
Vi1516VPD
Control Room Data
16
15
14
13
12
11
10
9
7
8
6
5
3
4
2
1
28 V
24 V
28 V
24 V
28 V
24 V
28 V
24 V
28 V
24 V
28 V
24 V
28 V
24 V
28 V
24 V
28 V
24 V
28 V
24 V
16-Ch Powered VPD Combiner-Transceiver
Rear View
Front View
Vi1516VPD
POWER
Control Room Data Connections:
Pin#
1
2
3
4
5
6
7
8
2
3
4
5
6
7
8
Data-1 +
Data-1 -
Data-2 +
Data-3 -
Data-3 +
Data-2 -
Data-4 +
Data-4 -
Data-1 -
Data-2 +
Data-3 -
Data-3 +
Data-2 -
Data-4 +
Data-4 -
Camera 1-4 Camera 5-8
Camera 9-12 Camera 13-16
Data-5 +
Data-5 -
Data-6 +
Data-7 -
Data-7 +
Data-6 -
Data-8 +
Data-8 -
Data-5 -
Data-6 +
Data-7 -
Data-7 +
Data-6 -
Data-8 +
Data-8 -
Data-9 +
Data-9 -
Data-10 +
Data-11 -
Data-11 +
Data-10 -
Data-12 +
Data-12 -
Data-9 -
Data-10 +
Data-11 -
Data-11 +
Data-10 -
Data-12 +
Data-12 -
Data-13 +
Data-13 -
Data-14 +
Data-15 -
Data-15 +
Data-14 -
Data-16 +
Data-16 -
Data-13 -
Data-14 +
Data-15 -
Data-15 +
Data-14 -
Data-16 +
Data-16 -
Included Accessories
Mounting brackets for front, rear or wall installations
Rubber feet for desk applications
16 2-ft. (60 cm) coax jumper cables
Moulded IEC 7-ft. (200 cm) power cord
Rubber feet for desk applications
16 2-ft. (60 cm) coax jumper cables
Moulded IEC 7-ft. (200 cm) power cord
Wire and Cable Recommendations
The Vigitron products are designed to be used with unshielded twisted pair (UTP) wiring. The UTP wire must be 24AWG - 12AWG or Category 2-7 cable.
Multi pair cable with an overall shield is acceptable, however individually shielded pairs should be avoided. Multiple UTP video feeds can be operated in
the same communication cable along with telephone, computer, control signals and low power voltages. While UTP video may be routed through
punch-down block terminals, any resistive, capacitive or inductive devices (such as T-taps or MOV's) must not be used. Please contact Vigitron for more
specific information regarding wire types and proper installation techniques.
Multi pair cable with an overall shield is acceptable, however individually shielded pairs should be avoided. Multiple UTP video feeds can be operated in
the same communication cable along with telephone, computer, control signals and low power voltages. While UTP video may be routed through
punch-down block terminals, any resistive, capacitive or inductive devices (such as T-taps or MOV's) must not be used. Please contact Vigitron for more
specific information regarding wire types and proper installation techniques.