SOEKS IMPULSE Magnetic field-analysis apparatus, Magnetic field tester 9 Datenbogen
Produktcode
9
Menu of the device
The device’s menu consists of 2 items:
- Main menu – device settings
- Measure – measurement of EMF level
Main menu
Settings
In this section you can preset the parameters for the device.
Items of the Settings menu:
● Vision
In this section you can adjust screen settings: brightness and display time.
●Brightness
Select low, medium or high brightness level of the screen.
To save power and help the batteries last longer it is recommended to use the
low or medium brightness level of the screen.
● OffTime, min.
Set the time of display backlight in standby mode. You can select from 1 to
15 minutes in the options list.
no – backlight is always on while the device is in use.
● Sound
In this section you can adjust the sound parameters.
● Enable (yes/no) — all instrument sounds
● KeyPad (yes/no) - button sound
● Alarm (yes/no) - audible alarm on standard threshold crossing.
For the purpose of power saving and extending battery lifetime it is
recommended to mute sounds.
● Tone
Select one of the 4 available sound tones.
● Volume (low/middle/high)
Default is the average volume.
-35-
Measurement rate, samples per second 2
Range of supply voltage of battery 1,8 - 3,3
or accumulator, V
USB supply voltage, V 4,6 - 5,5
USB consumption current, not more 300
than, mA
Accumulator charging current, not 200
more than, mA
Time of continuous work 10
of the device, hours at least
Overall dimensions 105х48х19
height х width х thickness, max, mm
Weight (without power elements), 60
max, grams
Display Color TFT, 128x160
Operating temperature range, °С from -20 to +45
Operating conditions
The indicator is operated under normal climatic conditions:
• Ambient temperature, °C: –20 to +45
• Relative humidity, %: 30 to 85