3.30  AGP – Accumulator to Global Parameter 
Description: The content of the accumulator register is transferred to the specified global parameter. For practical 
usage,  the  accumulator  has  to  be  loaded  e.g.  by  a  preceding  GAP  instruction.  The  accumulator  may  have  been 
modified by the CALC or CALCX (calculate) instruction. Note that the global parameters in bank 0 are EEPROM-only 
and thus should not be modified automatically by a stand-alone application. 
 
See chapter 6 for a complete list of global parameters.  
 
Related commands:
  AAP, SGP, GGP, SAP, GAP, GIO 
 
Mnemonic: AGP <parameter number>, <bank number> 
 
Binary representation: 
INSTRUCTION NO. 
TYPE 
MOT/BANK 
VALUE 
35 
<parameter 
number> 
<bank number> 
           (don't care) 
 
Reply in direct mode: 
STATUS 
VALUE 
100 – OK 
(don't care) 
 
Example: copy accumulator to TMCL user variable #3 
Mnemonic: AGP 3, 2 
 
Binary: 
Byte Index 
Function 
Target- 
address 
Instruction 
Number 
Type 
Motor/ 
Bank 
Operand 
Byte3 
Operand 
Byte2 
Operand 
Byte1 
Operand 
Byte0 
Checksum 
Value (hex) 
$01 
$23 
$03 
$02 
$00 
$00 
$00 
$00 
$29