Westinghouse EarthDirEX 19+ EER, 3.8+ COP Geothermal Direct Geoexchange Technisches Handbuch
The Y1SA Geothermal heat pump, Earth loops
and air handler are an incredibly quiet and
efficient way to heat and cool your home or
business. Because we are using the natural
energy from the Earth, you can reduce your
electric/utility bill by as much as 70%.
and air handler are an incredibly quiet and
efficient way to heat and cool your home or
business. Because we are using the natural
energy from the Earth, you can reduce your
electric/utility bill by as much as 70%.
Y1SA Series
EarthDirEX™ Geothermal
Direct Geoexchange
Heat Pump
Direct Geoexchange
Heat Pump
Cooling capacity 24,000 to 60,000
Heating capacity 21,000 to 57,000
EER 19.0 to 22.0 and COP 3.8 to 4.0
Heating capacity 21,000 to 57,000
EER 19.0 to 22.0 and COP 3.8 to 4.0
FEATURES and BENEFITS
• Single Stage - Copeland Scroll compressor
• Electronic Expansion Valve – one valve for precise
refrigerant control in all modes of operation
• Interface Control Board – Two digit LED provides
system operation, status and diagnostic information.
• Diagnostic: 12 event/fault codes provide
troubleshooting information
• System Protection: Internal controls monitor
system operation to protect the compressor.
• Three Minute Restart Time Delay: When the unit
shuts down, a delay keeps the unit from restarting,
eliminating the highest cause for compressor failure.
eliminating the highest cause for compressor failure.
• Micro-Channel – Indoor coil is all aluminum designed
to optimize heat transfer, minimize size and cost, and
increase durability and reliability.
increase durability and reliability.
• Earth Loop Seal Valve on 4 & 5 ton – captures
refrigerant in the outdoor Earth loop during off mode,
complies with ASHRAE Standard 15
complies with ASHRAE Standard 15
• Oil Separator - 99% efficient and has an internal filter,
installed at the factory. A second filter (shipped with the
unit) is to be used as a replacement in 24 to 48 hours
unit) is to be used as a replacement in 24 to 48 hours
• Hot Gas Bypass – Injected into evaporator to prevent
freeze up
• Accumulator– Protection from liquid flood back and
future compressor failures.
• Sight Glass- Included for simple indication of proper
refrigerant change.
• Sound Blanket – Is standard equipment
• Energy Efficient Brushless DC Blower Motor - ECM
constant torque in all models
• Improve aesthetics of your home - No exposed or
noisy outdoor equipment
• Simpler System - Our EarthDirEX™ geothermal
systems do not use a water to refrigerant heat exchanger,
or a pump to circulate the water
or a pump to circulate the water
TECHNICAL
SPECIFICATIONS
SPECIFICATIONS