Using Direct Immersion
1.
Apply pipe thread sealant 119400 over male
threads on pump.
threads on pump.
2.
GH833, 833ES Models Only: Attach female hose
adapter (22) over male threads on pump. Tighten
securely.
adapter (22) over male threads on pump. Tighten
securely.
3.
733ES, 933, 933ES, 5040ES Models Only: Add
bushing (34) to male threads of pump, then add
female hose adapter (22).
bushing (34) to male threads of pump, then add
female hose adapter (22).
4.
Apply pipe sealant to bushing (34).
5.
Position 55-gallon drum under pump assembly.
6.
Unclamp and tilt tower/bracket back to 1st position.
7.
Lock clamp into 1st position.
MOVING PARTS HAZARD
Moving parts can pinch or amputate fingers and other
body parts.
body parts.
• Keep clear of moving parts.
• Do not operate equipment with protective guards
or covers removed.
• Pressurized equipment can start without warning.
Before checking, moving, or servicing equipment,
follow the Pressure Relief Procedure in this
manual. Disconnect power or air supply.
follow the Pressure Relief Procedure in this
manual. Disconnect power or air supply.
apply
sealant
sealant
pump
22
ti20992a
22
34
34
ti20993a
pump
assembly
assembly
drum
55-gallon
clamp
ti7606a
1st position