Westinghouse WGR050LP076 Installationsanweisungen

Seite von 60
42 
 
 
                                                                                  WHL-001 REV. 12.17.14 
ECO Mode 
 
Putting the water heater into ECO Mode reduces maximum 
firing rate to 80% of the rated maximum firing rate. This 
increases water heater efficiency in times of low hot water 
demand. 
Press 
 to put the water heater into ECO mode. Press 
again to return to normal operation. 
ECO On / Off (Off) 
Test Mode 
 
Test Mode allows the installer to test water heater operation 
by running the fan at different speeds.  
To enter Test Mode, press 
 and 
 together for 5 
seconds. 
Push 
 to decrease or push 
  to increase fan speed by 
50 RPM increments. 
Push 
 to operate at maximum fan speed. 
Push 
to operate at minimum fan speed. 
Test Mode will exit automatically after 15 minutes. Press 
 
to leave Test Mode manually. 
Test Mode On / Off 
(Off)  
Lockout 
Fault Codes 
 
Lockout codes refer to a temporary condition that must be 
cleared to resume operation. If code persists, the heater 
should be serviced by a qualified service technician. 
Press 
 to clear 
the code. Observe 
operation to ensure 
code does not 
reoccur. 
Blocking 
Error Codes 
 
Blocking codes temporarily stop water heater operation until 
the error condition clears. Once the condition clears, the error 
will disappear and the water heater will resume operation. The 
error will also be written into the water heater’s history data. 
 
 
Water heater 
operation resumes 
when conditions 
return to normal. 
Installer 
Mode 
 
The Installer Mode allows installers to view history hidden 
from the user. 
 
See Advanced Control Functions for information on how to 
enter  
Installer Mode On / 
Off (Off) 
NOTE: 
 is a high temperature warning, and appears on the display if setpoint or actual water temperature is above 125
o
F. 
Water temperature over 125
o
F  can  instantly  cause  severe  burns  or  death  from  scalds.  Children,  disabled,  and elderly  are  at 
the highest risk of being scalded. 
Table 10 
– Water Heater Modes of Operation 
B. BASIC CONTROL FUNCTIONS 
There are a number of parameters accessible from the water heater main screen. These parameters are especially useful for the main 
user of the water heater. 
 
NOTE: These parameters ARE NOT ACCESSIBLE when the control is in a blocking or lockout state. 
1. TURNING WATER HEATER ON / OFF 
Press 
 to turn the water heater on / off. 
2. RESETTING THE WATER HEATER  
Press 
 to clear a fault code lockout and resume water heater operation. 
3. PUTTING THE WATER HEATER IN ECO MODE 
Press 
 to put the water heater into ECO Mode. Press 
 to resume normal operation.