Westinghouse WGR050LP076 Installationsanweisungen

Seite von 60
51 
 
 
                                                                                  WHL-001 REV. 12.17.14 
CONTROL BOARD LOCKOUT FAULTS 
CODE 
SHORT DESCRIPTION 
LONG DESCRIPTION 
CORRECTIVE ACTION 
F01 
Ignition Lockout Indication 
The control senses no flame after 
three ignition attempts.  
1. 
Is the gas turned on to the water heater? 
2. 
Manually reset the water heater. 
3. 
Observe water heater operation. If fault code occurs 
again 
4. 
Check for stable gas pressure. 
5. 
Check Ignitor cable connections. 
6. 
Check Ignitor cable gound. 
7. 
Replace cable. 
8. 
Check spark gap between spark electrode and burner. 
9. 
Replace ignitor. 
F02
 
False Flame Indication 
The control senses a flame signal 
when there is no heat demand. 
1. 
Visually check for flame through sight glass. 
2. 
Manually reset the water heater. 
3. 
Observe water heater operation. If fault code occurs 
again 
4. 
Check Ignitor cable connections 
5. 
Check Ignitor cable gound 
6. 
Replace cable 
7. 
Replace ignitor 
F03
 
High Limit Temperature 
Protection 
The control shuts down the water 
heater after it has met / surpassed 
the high temperature limit. 
1. 
Manually reset the water heater. 
2. 
Observe water heater operation. If fault code occurs 
again 
3. 
Check the Dual Temperature Sensor. Ensure it is 
properly wired to the control, and that there are no 
breaks, cuts, or other visible issues with the sensor wire. 
4. 
Use an ohmmeter to check resistance on first Sensor A, 
then Sensor B of the Dual Temperature Sensor. 
5. 
Replace Dual Temperature Sensor if either Sensor A or 
Sensor B fails the resistance test.
 
F05
 
Incorrect Fan Speed 
The control detects incorrect fan 
speed. 
1. 
Manually reset the water heater. 
2. 
Observe water heater operation. If fault code occurs 
again 
3. 
Check condition of wiring 
4. 
Check Fan PWM connections at control board and fan 
5. 
Replace fan 
F07
 
Vent Temperature Too High 
The vent temperature has met / 
surpassed the maximum limit. This is 
first an E07 blocking error code. If 
vent temperature has not returned to 
normal levels within 15 minutes, this 
becomes an F07 lockout fault code. 
1. 
Manually reset the water heater. 
2. 
Observe water heater operation. If fault code occurs 
again 
3. 
Replace sensor 
4. 
Measure actual vent temperature. 
F08
 
Flame Circuit Failure 
The control detects an incorrect 
flame level. 
1. 
Manually reset the water heater. 
2. 
Observe water heater operation. If fault code occurs 
again 
3. 
Check Ignitor cable connections 
4. 
Check Ignitor cable gound 
5. 
Replace cable 
6. 
Check spark gap between spark electrode and burner. 
7. 
Replace ignitor 
F09
 
Valve Feedback Error 
The gas valve does not respond to 
controller demands. 
1.  Manually reset the water heater. 
2.  Observe water heater operation. If fault code occurs 
again, reset the water heater and: 
3.  When water heater attempts to fire, check voltage at the 
gas valve connector. If there is voltage, but no gas 
pressure on the outlet side of the valve, the valve is stuck 
closed. Replace the gas valve. 
4.  If there is no voltage at the ignition phase, replace the 
control board. 
F12 
EEPROM Integrity Lockout 
The EEPROM check fails. EEPROM 
data is corrupted. 
1. 
Manually reset the water heater. 
2. 
Observe water heater operation. 
3. 
If fault code occurs again, replace controller.