ALTERNATIVES FOR WALL PROTECTION
 
 
Example:  The rear clearance for the Model 80 from page 12 is 26". (Measurement A.) This clearance may be 
reduced by 66% by using either of the wall protection devices mentioned below. 
 
Tested and Listed Wall Protector 
 
Clearances to combustibles may be reduced if a tested and listed wall protector is installed over a combustible 
surface when the following condition exist
1.  A dead air space or 1" separates the listed and tested wall protector from the combustible surface. 
2.  The tested and listed wall protector extends from floor to ceiling with a 1" clearance for air circulation at both 
the floor and ceiling. 
3.  The 1" spacers (preferable ceramic rather than metal) must be located at the corners rather than behind the 
heater or the chimney connector. 
 
Unlisted and Untested Wall Protector
 
 
Wall protectors may be constructed of masonry, 24 gauge or thicker sheet metal, or non-combustible 1/2" thick 
insulation board. Conditions 2 and 3 above must be observed but the air space in condition 1 must be increased to 1 
1/2". 
 
FINAL CHECK
 
1.  Recheck the specified clearances. 
2.  Remove all foreign material from the firebox area. 
BRICK  
CLEARANCE 
REDUCTION 
SYSTEM 
BRICK WALL SPACED 
OUT  1 INCH FROM 
PROTECTED SURFACE 
AIR CIRCULATION 
LEAVE 1 INCH 
CLEARANCE FOR AIR 
CIRCULATION 
FLOOR 
AIRSPACE 
COMBUSTIBLE 
WALL 
1” 
NAIL OR 
SCREW   
ANCHOR 
MINIMUM  
24 GAUGE 
SHEET 
METAL 
1 INCH NON-COMBUSTIBLE  SPACER SUCH AS STACKED WASH-
ERS, SMALL DIAMETER PIPE, TUBING, OR ELECTRICAL CON-
DUIT. 
DO NOT USE FASTENERS DIRECTLY BEHIND CHIM-
NEY CONNECTOR OR STOVE 
COMBUSTIBLE 
WALL 
   TOP VIEW 
NON-COMBUSTIBLE 
SPACERS  
MINIMUM        
24 GAUGE 
SHEET METAL 
  
FLOOR PROTECTOR 
SHEET METAL CLEARANCE REDUCTION SYSTEM 
   FIGURE   12 
BRICK WALLS MAY BE ATTACHED TO COMBUSTIBLE WALLS 
USING WALL TIES. IF BRICK IS USED,  BE  SURE FLOOR CAN  
WITHSTAND THE WEIGHT OF THE BRICK. 
   COMBUSTIBLE  WALL 
WOOD STOVE 
CLEARANCE RE-
DUCTION SYSTEM 
SPACED OUT 1 
INCH. 
16