PROBLEM 
CAUSES 
SOLUTIONS 
 
?  Fire burns with a lazy, orange flame 
and/or fuel builds up in the grate and the 
window gets sooted up. 
 
♦  Insufficient combustion air. 
 
♦  Feed rate too high. 
 
♦  Corn or wood pellets have too 
much moisture – need 14% or less; 
10%-12% is ideal. 
 
♦  Combustion/Exhaust blower 
plugged or going out. 
 
♦  Venting plugged with fly ash or ice. 
 
♦  House does not have adequate 
make up air (negative pressure) 
 
♦   
 
 
9
  Remove any clinkers or ash from 
the firepot by using scraping tool.  
Shake ashes into ash pan.  
 
9
  Clean out primary air in firepot 
holes if plugged. 
 
9
  Empty ash drawer and clean out 
back heat exchanger by removing 
the lower access plates. 
 
9
  Tap the side exhaust heat 
exchangers to clean them as shown 
on page 23 & 24. 
 
9
  Change to a better grade of fuel if 
necessary.  See page 5-6 regarding 
fuel quality. 
 
9
  Check that damper control knob is 
adjusted properly.  Pull out to 
increase fire burn. 
 
9
  Check gasket seal around the door.  
If the door is loose, adjust the 
handle latch.  A small adjustment 
can be made to the door seal by 
adjusting the door latch rod and /or 
the door hinges.  Replace the door 
gasket if necessary. 
 
9
  Check for blockage in the air inlet 
tube or exhaust pipe.  Clean out as 
necessary. 
 
9
  Check combustion exhaust blower 
impeller.  This can be done by 
removing the exhaust pipe and 
shining a light into the tube.   
 
9
  Replace combustion exhaust blower 
if necessary. 
 
NOTE: 
Negative pressure in a home is 
a serious issue.  All Countryside 
appliances should be installed with 
outside air hookups 
Also make sure that adequate ventilation 
is supplied for the rest of the home or 
the unit will become the air intake 
causing problems. 
 
 
TROUBLE SHOOTING GUIDE 
Unplug stove before performing any maintenance work.  Do not work on unit when it is hot.