Lide Glass Lid J3500 Benutzerhandbuch

Seite von 39
 
33
PROBLEM 
CAUSES 
SOLUTIONS 
Fuel burns off to quickly, have difficulty 
keeping a pilot fire. 
Air shutter is open to far. 
 
Over drafting on a vertical install. 
Outside air is not hooked up 
Positive or negative pressure in home is 
affecting the units operation 
 
Adjust your air shutter to a more closed 
position. 
 
A chimney restrictor may need to be 
installed. Consult with your Countryside 
dealer. 
Make sure that the installation is correct 
and nothing is affecting the furnace room 
Foreign object caught in the auger and 
will not turn. 
Accidental object in fuel. 
If there still is a fire, let it extinguish and 
let furnace cool down. Unplug unit after 
the fire  has exhausted. It will be necessary 
to clean out hopper. As you are facing the 
furnace open the right hand side panel. The 
auger motor will have a small cooling fan 
on the back. Turn the fan counter 
clockwise until tension is off the auger. 
Open the front door of the unit and pull the 
auger out. Prying on the auger without 
loosening first can damage auger gear box. 
Getting to much ash. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Dirty fuel 
 
Wet fuel 
 
Lack of clean combustion air. 
 
Dirty or plugged stove or venting. Poor 
exhaust vent configuration. 
 
Negative pressure present in the home 
 
Combustion motor going out. 
 
Use combustion enhancement system 
 
 
Adequately screen corn. Dirty , wet fuel 
will produce excessive ash 
 
Take proper steps to check corn for proper 
moisture and to adequately protect from 
the elements to not take on moisture. 
 
Check damper control and check 
combustion air inlet for obstructions. 
 
Check all cleanouts and exhaust venting 
for obstructions. Refer to cleaning section 
of this manual.  
 
Call your Countryside reseller to inspect 
installation and operation.  Replace any 
bad parts. 
 
On higher heat settings combustion 
enhancement system will keep ash 
volume down.
 
The heat output is not as high as when 
the furnace was installed. 
Wet or dirty fuel. 
 
Inadequate cleaning. 
 
Dirty room air filter. 
 
Change of fuel to lower BTU value 
 
Negative pressure or improper ductwork 
is causing unit to perform improperly 
Wet fuel has a much lower BTU output. 
The furnace requires 14% or lower 
moisture corn. Dirty fuel does not produce 
adequate heat.  Excessive amounts of fines 
interrupt the amount of corn delivered for 
burning and will decrease heat output. 
 
Clean heat exchangers daily, tap side 
exchangers, inspect furnace for air flow. 
Clean or replace filter. 
 
Have dealer check for proper installation 
and negative pressure in home. 
WARNING: This section is only for qualified technicians.