ACCU-CHEK Spirit Insulin Pump
198
program
profile no. 
5
program
profile no. 
4
program 
profile no. 
3
program 
profile no
.
2
Standard
bolus
stop your
Accu-Chek
«Scroll» Stan-
dard bolus
bolus
amount
Extended
bolus
bolus
amount
bolus
duration 
temporary
basal rate
percentage
duration
select the
user menu
user menu
BR profile 
no.…
information
menu
bolus
history
alarm
history
daily insulin
totals
TBR history
maintenance
set the time
and date
set the
hour
set the 
minute
set the
year
set the 
month
set the
day
setup menu
standard
display
orientation
KeyLock
beep
volume
alarm
signals
automatic
off
battery
type
program 
profile no. 1
daily basal
rate total
1st hour
2nd hour
24th hour
KeyLock
quick info 
MultiWave
bolus
bolus
amount
immediate
bolus
bolus
duration
change your
BR profile
BR profile
no. …
alarm clock
alarm
occurance
alarm
hour
alarm
minute
setup menu
advanced
time
format
date
format
bolus
increment
prime
quantity
basal
rate lock
language
display
contrast
Standard
bolus
stop your
Accu-Chek
«Scroll» Stan-
dard bolus
bolus
amount
temporary
basal rate
percentage
duration
select the
user menu
user menu
BR profile 
no.…
information
menu
bolus
history
alarm
history
daily insulin
totals
TBR history
maintenance
set the time
and date
set the
hour
set the 
minute
set the
year
set the 
month
set the
day
setup menu
standard
display
orientation
KeyLock
beep
volume
alarm
signals
automatic
off
battery
type
program 
profile no.1
daily basal
rate total
1st hour
2nd hour
24th hour
KeyLock
quick info 
Your Insulin pump ADVANCED MENU
Your Insulin pump STANDARD MENU
Standard
bolus
 
KeyLock
quick info 
stop
priming 
prime the
infusion set
start
priming 
communi-
cation 
data transfer
to PC 
returning the
piston rod
change the
cartridge 
remove the
cartridge 
fill volume
315 units 
start-up
procedure
start your
Accu-Chek
KeyLock
quick info 
start your
Accu-Chek
stop
priming 
prime the
infusion set
start
priming 
communi-
cation 
data transfer
to PC 
returning the
piston rod
change the
cartridge 
remove the
cartridge 
fill volume
315 units 
start-up
procedure
(A) «Quick» 
with direct access from the RUN screen 
Standard bolus  using the a
and s
keys of your
insulin pump.
(B) «Scroll» 
menu-guided using the STANDARD BOLUS
Standard bolus  menu and the scroll function of the a
and s
keys for programming the bolus amount.
For a complete review of your insulin pump features as well as
the warnings and precautions associated with its use, please 
refer to your ACCU-CHEK Spirit Insulin Pump User Guide.
Diagram of User Menus
199
Quick Reference Table for Alerts
In all cases, turn off and confirm the alert prior to addressing the issue.
No. Alert
What You Need to Do
A1
CARTRIDGE LOW
Change cartridge before it is completely
empty.
A2
BATTERY LOW
Replace the battery as soon as possible.
A3
REVIEW TIME AND DATE
Set the time and date.
A4
ALARM CLOCK
Put your ACCU-CHEK Spirit in RUN mode,
if necessary.
A5
PUMP TIMER
Your pump’s operating time will expire
soon. Go to the INFORMATION screen on
your pump, then move to the PUMP TIMER
screen. The days until the pump timer
expires is shown. Make arrangements for
replacement of the pump before the timer
reaches zero days.
A6
TBR CANCELLED
Put your ACCU-CHEK Spirit insulin pump in
RUN mode, if necessary. Ensure the can-
cellation was intended and program a new
Temporary Basal Rate, if necessary.
A7
TBR OVER
Decide whether a further Temporary Basal
Rate change is appropriate and program
one, if necessary.
A8
BOLUS CANCELLED
Put your ACCU-CHEK Spirit insulin pump in
RUN mode, if necessary. Ensure that the
cancellation was intended and program a
new bolus, if necessary.
Quick Reference Table for Alerts
ACCU-CHEK Spirit Insulin Pump